Miniaturized low-field thoracic magnetic stimulation device for assessing effects on peripheral oxygen saturation levels in healthy rats

<i>Objective.</i>This study aimed to develop a miniaturized low-field thoracic magnetic stimulation (LF-ThMS) device to evaluate its effects on peripheral oxygen saturation (SpO<sub>2</sub>) in healthy rats. This investigation was motivated by prior findings that LF-ThMS at 10.5 to 13.1 mT increased SpO<sub>2</sub>in patients with COVID-19. However, its effect on healthy subjects remains unknown. To address this gap before extending research to healthy humans, we first examined its effects in healthy animal models.<i>Approach.</i>A miniature low-field thoracic magnetic stimulation (LF-ThMS) device, also referred to as a pulsed electromagnetic field (PEMF) system, was developed using two 30-turn coils made of 13-gauge magnet wire, encased in nylon sheaths. The coils were powered by a 30 V, 13 A DC source to generate magnetic pulses up to 13.1 mT. A custom control circuit, featuring an ATmega328P microcontroller, relays, and MOSFETs, regulated the pulse frequency and included a safety system to maintain coil temperatures below 38 °C. The device also featured a user interface for customizable and reproducible operation. Peripheral oxygen saturation (SpO<sub>2</sub>) was monitored using a NONIN 750 pulse oximeter.<i>Main results.</i>The LF-ThMS device successfully generated magnetic flux densities of 10.5, 11.6, and 13.1 mT. However, when we compared SpO<sub>2</sub>levels between the control condition (before LF-ThMS) and the SpO<sub>2</sub>levels after the LF-ThMS at these intensities, we did not find a statistically significant difference. S<i>ignificance.</i>These results suggest that LF-ThMS may not affect SpO<sub>2</sub>in healthy individuals, and the improvements observed in COVID-19 patients could be due to disease-specific mechanisms or other unknown factors, rather than a general physiological effect of LF-ThMS.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-11-26
DOI
https://doi.org/10.1088/2057-1976/ae2489
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Miniaturized low-field thoracic magnetic stimulation device for assessing effects on peripheral oxygen saturation levels in healthy rats

Saúl M. Domínguez-Nicolás, Amira Flores, Elı́as Manjarrez, J. Marta Moreno
Biomedical Physics & Engineering Express
Non-Invasive Vital Sign Monitoring
article

Miniaturized low-field thoracic magnetic stimulation device for assessing effects on peripheral oxygen saturation levels in healthy rats

Saúl M. Domínguez-Nicolás, Amira Flores, Elı́as Manjarrez, J. Marta Moreno
article en

Abstract

<i>Objective.</i>This study aimed to develop a miniaturized low-field thoracic magnetic stimulation (LF-ThMS) device to evaluate its effects on peripheral oxygen saturation (SpO<sub>2</sub>) in healthy rats. This investigation was motivated by prior findings that LF-ThMS at 10.5 to 13.1 mT increased SpO<sub>2</sub>in patients with COVID-19. However, its effect on healthy subjects remains unknown. To address this gap before extending research to healthy humans, we first examined its effects in healthy animal models.<i>Approach.</i>A miniature low-field thoracic magnetic stimulation (LF-ThMS) device, also referred to as a pulsed electromagnetic field (PEMF) system, was developed using two 30-turn coils made of 13-gauge magnet wire, encased in nylon sheaths. The coils were powered by a 30 V, 13 A DC source to generate magnetic pulses up to 13.1 mT. A custom control circuit, featuring an ATmega328P microcontroller, relays, and MOSFETs, regulated the pulse frequency and included a safety system to maintain coil temperatures below 38 °C. The device also featured a user interface for customizable and reproducible operation. Peripheral oxygen saturation (SpO<sub>2</sub>) was monitored using a NONIN 750 pulse oximeter.<i>Main results.</i>The LF-ThMS device successfully generated magnetic flux densities of 10.5, 11.6, and 13.1 mT. However, when we compared SpO<sub>2</sub>levels between the control condition (before LF-ThMS) and the SpO<sub>2</sub>levels after the LF-ThMS at these intensities, we did not find a statistically significant difference. S<i>ignificance.</i>These results suggest that LF-ThMS may not affect SpO<sub>2</sub>in healthy individuals, and the improvements observed in COVID-19 patients could be due to disease-specific mechanisms or other unknown factors, rather than a general physiological effect of LF-ThMS.

Biomedical Physics & Engineering ExpressVol. 12(1)
Universidad Veracruzana (MX), Benemérita Universidad Autónoma de Puebla (MX)
Openalex Percentile: Top 64%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.