Bronchoscope Inversion during Transbronchial Biopsy with a Guide Sheath for a Right Upper Lobe Lesion

Bronchoscopic inversion may occur intraoperatively. This can make bronchoscopic handling difficult and cause bronchial wall injury; however, there have been only a few reported cases. A 68-year-old man was referred to our hospital for further evaluation of a right upper lobe mass lesion suspected to be lung cancer. Endobronchial ultrasound transbronchial biopsy with a guide sheath (EBUS-GS-TBB) was performed for further examination. During bronchial brushing from the right B1aiα, the bronchoscope was inverted on the bronchoscopic view, and fluoroscopy confirmed that the tip of the bronchoscope had formed a loop in the intermediate bronchus. Under fluoroscopic guidance, the bronchoscope was advanced into the left main bronchus and withdrawn by gentle clockwise rotation, and the inversion was released. In conducting procedures that require deep peripheral insertion of a thin bronchoscope, such as EBUS-GS-TBB, for right upper lobe lesions, the inversion should be handled carefully, and operators should not push it extremely hard. To release the inversion, operators should not try to pull it out forcibly but should check the overall image of the bronchoscope under fluoroscopy.

Authors

Institutions

Publication Details

Journal
Respiratory Endoscopy
Published
2025-11-26
DOI
https://doi.org/10.58585/respend.2025-0009
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bronchoscope Inversion during Transbronchial Biopsy with a Guide Sheath for a Right Upper Lobe Lesion

Atsuhiko Yatani, Motoko Tachihara, Daisuke Hazama, Naoko Katsurada et al.
Respiratory Endoscopy
Medical Device Sterilization and Disinfection
article

Bronchoscope Inversion during Transbronchial Biopsy with a Guide Sheath for a Right Upper Lobe Lesion

Atsuhiko Yatani, Motoko Tachihara, Daisuke Hazama, Naoko Katsurada, Mizuki Takayasu
article en

Abstract

Bronchoscopic inversion may occur intraoperatively. This can make bronchoscopic handling difficult and cause bronchial wall injury; however, there have been only a few reported cases. A 68-year-old man was referred to our hospital for further evaluation of a right upper lobe mass lesion suspected to be lung cancer. Endobronchial ultrasound transbronchial biopsy with a guide sheath (EBUS-GS-TBB) was performed for further examination. During bronchial brushing from the right B1aiα, the bronchoscope was inverted on the bronchoscopic view, and fluoroscopy confirmed that the tip of the bronchoscope had formed a loop in the intermediate bronchus. Under fluoroscopic guidance, the bronchoscope was advanced into the left main bronchus and withdrawn by gentle clockwise rotation, and the inversion was released. In conducting procedures that require deep peripheral insertion of a thin bronchoscope, such as EBUS-GS-TBB, for right upper lobe lesions, the inversion should be handled carefully, and operators should not push it extremely hard. To release the inversion, operators should not try to pull it out forcibly but should check the overall image of the bronchoscope under fluoroscopy.

Respiratory EndoscopyVol. 3(3)
Kobe University (JP)
Openalex Percentile: Top 65%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.