Effect of wire rupture on the mechanical behaviour of an external prestressing tendon

External prestressing is a construction technique widely employed since the 1980s for large civil engineering structures to reduce the cross-sectional area of structures and thus their permanent load, and more recently to reinforce structures. External prestressing tendons are composed of strands, each comprising 7 wires with a very high elastic limit, laid in a HDPE sheath, anchored in reinforced concrete blocks and generally tensioned to 80% (excluding creep and shrinkage) of their ultimate tensile strength. To safeguard the cables, grout was injected into the sheaths. However, this protection system has not always prevented the corrosion of the strands. When wires and strands re-anchor through friction in the grout after fracturing due to corrosion, the stress on the remaining tendon increases until the breaking load of the entire tendon is reached. The sudden release of energy from such a break can jeopardize the structure and endanger any personnel present on-site. Therefore, understanding the state of the cable at a given level of degradation and the permissible degradation before failure is crucial for structure managers. Several 46 m long cables between supports were tested and brought to failure by the progressive cutting of the wires composing the strands. Initially, three tendons, each comprising a single strand of seven wires, were tested. Subsequently, three tendons, each comprising five strands, were examined. The experiments conducted and the analysis of the results have enhanced the understanding of the evolution of tension in the tendon as it becomes damaged. To this end, a model was developed to estimate the length affected by wire ruptures. This work also presents findings regarding the transfer of stresses within the tendon and strands resulting from these ruptures. Finally, a model that estimates tension loss due to the sliding of wires after they break is presented. • Damage has been reproduced wire-wise for external prestressing tendon. • Breaking occur after around a third wires break. • Tension loss is minimal. • Re-anchoring length and tension loss can be estimated using damage level.

Authors

Institutions

Publication Details

Journal
Construction and Building Materials
Published
2025-11-26
DOI
https://doi.org/10.1016/j.conbuildmat.2025.144628
Primary Topic
Concrete Properties and Behavior
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of wire rupture on the mechanical behaviour of an external prestressing tendon

Gwendal Cumunel, Gilles Forêt, Tien Hoang, Jonas Aparicio
Construction and Building Materials
Concrete Properties and Behavior
article

Effect of wire rupture on the mechanical behaviour of an external prestressing tendon

Gwendal Cumunel, Gilles Forêt, Tien Hoang, Jonas Aparicio
article en

Abstract

External prestressing is a construction technique widely employed since the 1980s for large civil engineering structures to reduce the cross-sectional area of structures and thus their permanent load, and more recently to reinforce structures. External prestressing tendons are composed of strands, each comprising 7 wires with a very high elastic limit, laid in a HDPE sheath, anchored in reinforced concrete blocks and generally tensioned to 80% (excluding creep and shrinkage) of their ultimate tensile strength. To safeguard the cables, grout was injected into the sheaths. However, this protection system has not always prevented the corrosion of the strands. When wires and strands re-anchor through friction in the grout after fracturing due to corrosion, the stress on the remaining tendon increases until the breaking load of the entire tendon is reached. The sudden release of energy from such a break can jeopardize the structure and endanger any personnel present on-site. Therefore, understanding the state of the cable at a given level of degradation and the permissible degradation before failure is crucial for structure managers. Several 46 m long cables between supports were tested and brought to failure by the progressive cutting of the wires composing the strands. Initially, three tendons, each comprising a single strand of seven wires, were tested. Subsequently, three tendons, each comprising five strands, were examined. The experiments conducted and the analysis of the results have enhanced the understanding of the evolution of tension in the tendon as it becomes damaged. To this end, a model was developed to estimate the length affected by wire ruptures. This work also presents findings regarding the transfer of stresses within the tendon and strands resulting from these ruptures. Finally, a model that estimates tension loss due to the sliding of wires after they break is presented. • Damage has been reproduced wire-wise for external prestressing tendon. • Breaking occur after around a third wires break. • Tension loss is minimal. • Re-anchoring length and tension loss can be estimated using damage level.

Construction and Building MaterialsVol. 504
Centre National de la Recherche Scientifique (FR), École nationale des ponts et chaussées (FR), Laboratoire Navier (FR), Université Gustave Eiffel (FR)
Openalex Percentile: Top 62%
Concrete Properties and Behavior
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.