A Battery-Free Neural Implant Achieving 6cm Reading Range and 36.2pJ/Bit Efficiency by PWM Passive Body-Channel Communication

Minimally invasive wireless implants distributed in the nervous system can transfer various neural signals to an external device, offering an effective hardware tool for neuro-disorder monitoring. Battery-free wireless techniques based on wireless power transfer (WPT) have been adopted to minimize the neural implants, but the effective reading ranges of most conventional works are not long enough to access deep-tissue nerves. The existing ultrasonic coupling and binary-driven passive body-channel-communication (BCC) techniques extended the reading range but suffered from a low data rate and a high energy in wireless communication. In this work, we demonstrate a battery-free wireless neural implant based on the proposed pulse-width-modulation (PWM) passive-BCC technique, which improves the data rate and further reduces the energy per bit. The proposed technique is implemented in a neural-recording chip fabricated by a 65nm CMOS process. Measured results show that the proposed wireless neural implant achieves a battery-free reading range of 6cm, with an energy efficiency of 36.2pJ/bit. In-vivo experiment is performed in a Sprague-Dawley rat to record the neural signals wirelessly in a battery-free way.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2025-11-24
DOI
https://doi.org/10.1109/tbcas.2025.3635731
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Battery-Free Neural Implant Achieving 6cm Reading Range and 36.2pJ/Bit Efficiency by PWM Passive Body-Channel Communication

Yunshan Zhang, Changgui Yang, Bo Zhao, Yili Shen et al.
IEEE Transactions on Biomedical Circuits and Systems
Wireless Power Transfer Systems
article

A Battery-Free Neural Implant Achieving 6cm Reading Range and 36.2pJ/Bit Efficiency by PWM Passive Body-Channel Communication

Yunshan Zhang, Changgui Yang, Bo Zhao, Yili Shen, Kedi Xu, Weixiao Wang, Gang Pan, Chaonan Yu
article en

Abstract

Minimally invasive wireless implants distributed in the nervous system can transfer various neural signals to an external device, offering an effective hardware tool for neuro-disorder monitoring. Battery-free wireless techniques based on wireless power transfer (WPT) have been adopted to minimize the neural implants, but the effective reading ranges of most conventional works are not long enough to access deep-tissue nerves. The existing ultrasonic coupling and binary-driven passive body-channel-communication (BCC) techniques extended the reading range but suffered from a low data rate and a high energy in wireless communication. In this work, we demonstrate a battery-free wireless neural implant based on the proposed pulse-width-modulation (PWM) passive-BCC technique, which improves the data rate and further reduces the energy per bit. The proposed technique is implemented in a neural-recording chip fabricated by a 65nm CMOS process. Measured results show that the proposed wireless neural implant achieves a battery-free reading range of 6cm, with an energy efficiency of 36.2pJ/bit. In-vivo experiment is performed in a Sprague-Dawley rat to record the neural signals wirelessly in a battery-free way.

IEEE Transactions on Biomedical Circuits and SystemsVol. 20(2)
Zhejiang Lab (CN), Zhejiang University (CN)
Openalex Percentile: Top 64%
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.