Equilibrium state dynamics‐based modeling of temporal dose delivery dependencies of FLASH skin sparing

ESD-based modeling offers an effective framework to describe TDD dependencies of FLASH murine skin sparing while limiting complexity and number of free parameters to avoid overfitting. Through parameter tuning, the ESD modeling aligns with key experimental data, supporting its potential as a predictive, parsimonious framework for experimental and translational research. By highlighting the potential role of a transient equilibrium perturbation modulating instantaneous radiosensitivity and quantifying respective measures, ESD-based models may also guide the exploration and modeling of underlying mechanisms. While the present application is tissue-specific, the approach is broadly adaptable, with clinical translation requiring refitting and validation in other contexts.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-11-21
DOI
https://doi.org/10.1002/mp.70143
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Equilibrium state dynamics‐based modeling of temporal dose delivery dependencies of FLASH skin sparing

Raphaël Moeckli, Till T. Böhlen, Brita Singers Sørensen, P.R. Poulsen et al.
Medical Physics
Advancements in Transdermal Drug Delivery
article

Equilibrium state dynamics‐based modeling of temporal dose delivery dependencies of FLASH skin sparing

Raphaël Moeckli, Till T. Böhlen, Brita Singers Sørensen, P.R. Poulsen, Claude Bailat, Veljko Grilj, Fernanda Herrera, François Bochud, Jean-François Germond, P Devanand, Anouk Sesink, Luca Soutter
article en

Abstract

ESD-based modeling offers an effective framework to describe TDD dependencies of FLASH murine skin sparing while limiting complexity and number of free parameters to avoid overfitting. Through parameter tuning, the ESD modeling aligns with key experimental data, supporting its potential as a predictive, parsimonious framework for experimental and translational research. By highlighting the potential role of a transient equilibrium perturbation modulating instantaneous radiosensitivity and quantifying respective measures, ESD-based models may also guide the exploration and modeling of underlying mechanisms. While the present application is tissue-specific, the approach is broadly adaptable, with clinical translation requiring refitting and validation in other contexts.

Medical PhysicsVol. 52(12)
Aarhus University Hospital (DK), Institute of Radiation Physics (CH), University of Lausanne (CH)
Openalex Percentile: Top 70%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Equilibrium state dynamics‐based modeling of temporal dose delivery dependencies of FLASH skin sparing — Raphaël Moeckli, Till T. Böhlen, et al. · Medical Physics (2025) | TGRS Research Map | TGRS