Dimensionality-tailored pure organic semiconductor with high hole mobility for low-dose x-ray imaging

Pure-organic semiconductors have attracted broad interest in tissue-equivalent and biocompatible X-ray sensors, while their low-dose X-ray imaging capability still suffers from poor charge transport properties. Here, we report a dimensionality tailoring method to enhance hole transport in pure-organic semiconductors, enabling highly stable and low-dose X-ray detection and imaging without toxic elements such as Pb or Hg. By substituting the -CN group in 4-hydroxycyanobenzene (4HCB, HO-C<sub>6</sub>H<sub>4</sub>-CN) with a -COOCH<sub>3</sub> group, we transform the two-dimensional (2D) structure into a three-dimensional (3D) 4-methyl hydroxybenzoate (4MHB, HO-C<sub>6</sub>H<sub>4</sub>-COOCH<sub>3</sub>) crystal featuring enhanced intermolecular π-π stacking. This structural reconfiguration yields a high hole mobility of 19.91 cm<sup>2</sup> V<sup>-1</sup> s<sup>-1</sup> and an ultralow dark current drift of 1.14 × 10<sup>-10 </sup>nA cm<sup>-1</sup> s<sup>-1</sup> V<sup>-1</sup> at 100 V mm<sup>-1</sup>. The superior charge transport facilitated by stronger π-π interactions enables stable X-ray detection with a detection limit as low as 4.22 nGy<sub>air</sub> s<sup>-1</sup> and high-resolution imaging at 1.6 lp mm<sup>-1</sup> under low-dose irradiation (58.76 μGy<sub>air</sub> s<sup>-1</sup>). This work demonstrates a molecular tailoring strategy to modulate the structural dimensionality and the charge transport path of pure-organic semiconductors, advancing tissue-equivalence and biocompatible X-ray imagers toward high-resolution and low-dose operation.

Authors

Institutions

Publication Details

Journal
Nature Communications
Published
2025-11-24
DOI
https://doi.org/10.1038/s41467-025-65349-z
Citations
1
Primary Topic
Covalent Organic Framework Applications
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dimensionality-tailored pure organic semiconductor with high hole mobility for low-dose x-ray imaging

Huaiyu Zhang, Donghao Ma, Zhiyu Zheng, Dou Zhao et al.
1 citations
Nature Communications
Covalent Organic Framework Applications
0.52
article

Dimensionality-tailored pure organic semiconductor with high hole mobility for low-dose x-ray imaging

Huaiyu Zhang, Donghao Ma, Zhiyu Zheng, Dou Zhao, Wei Zheng, Zixuan Jia, Long Zhou, Chen Li, Yadong Xu, Zhihui Gao, Jiahao Geng, Meng Xu, Xinkai Peng, Wanqi Jie, Mengyao Liu
article en
1 citations

Abstract

Pure-organic semiconductors have attracted broad interest in tissue-equivalent and biocompatible X-ray sensors, while their low-dose X-ray imaging capability still suffers from poor charge transport properties. Here, we report a dimensionality tailoring method to enhance hole transport in pure-organic semiconductors, enabling highly stable and low-dose X-ray detection and imaging without toxic elements such as Pb or Hg. By substituting the -CN group in 4-hydroxycyanobenzene (4HCB, HO-C<sub>6</sub>H<sub>4</sub>-CN) with a -COOCH<sub>3</sub> group, we transform the two-dimensional (2D) structure into a three-dimensional (3D) 4-methyl hydroxybenzoate (4MHB, HO-C<sub>6</sub>H<sub>4</sub>-COOCH<sub>3</sub>) crystal featuring enhanced intermolecular π-π stacking. This structural reconfiguration yields a high hole mobility of 19.91 cm<sup>2</sup> V<sup>-1</sup> s<sup>-1</sup> and an ultralow dark current drift of 1.14 × 10<sup>-10 </sup>nA cm<sup>-1</sup> s<sup>-1</sup> V<sup>-1</sup> at 100 V mm<sup>-1</sup>. The superior charge transport facilitated by stronger π-π interactions enables stable X-ray detection with a detection limit as low as 4.22 nGy<sub>air</sub> s<sup>-1</sup> and high-resolution imaging at 1.6 lp mm<sup>-1</sup> under low-dose irradiation (58.76 μGy<sub>air</sub> s<sup>-1</sup>). This work demonstrates a molecular tailoring strategy to modulate the structural dimensionality and the charge transport path of pure-organic semiconductors, advancing tissue-equivalence and biocompatible X-ray imagers toward high-resolution and low-dose operation.

Nature CommunicationsVol. 16(1)
Northwestern Polytechnical University (CN), University of Tokyo Hospital (JP)
National Natural Science Foundation of China, Natural Science Foundation of Shaanxi Province, Japan Society for the Promotion of Science, National Key Research and Development Program of China
Openalex Percentile: Top 30%
Covalent Organic Framework Applications
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.