Isotope-Specific Quantitative Mapping of <sup>90</sup> Sr at Subfemtogram Levels via Online Isotope Dilution and Laser Ablation Inductively Coupled Plasma Tandem Mass Spectrometry

The quantitative mapping of radioisotopes in solids is crucial for understanding their microscale localization and migration. However, conventional radiometric and mass spectrometric techniques are only capable of bulk measurements without spatial resolution. Imaging plates provide spatial resolution, but they lack selectivity and cannot quantify radioisotopes that only emit beta radiation, such as <sup>90</sup>Sr. Here, the first system for isotope-specific quantitative mapping of a pure beta emitter is demonstrated, integrating online isotope dilution (ID) with laser ablation inductively coupled plasma tandem mass spectrometry (LA-ICP-MS/MS). In a case study, ultratrace levels of <sup>90</sup>Sr were accurately quantified without requiring matrix-matched certified reference materials (CRMs) for calibration or chemical separation. Severe isobaric/polyatomic interference (e.g., <sup>90</sup>Zr<sup>+</sup>, <sup>74</sup>Ge<sup>16</sup>O<sup>+</sup>, <sup>89</sup>Y<sup>1</sup>H<sup>+</sup>, and <sup>58</sup>Ni<sup>16</sup>O<sub>2</sub><sup>+</sup>) was efficiently suppressed by O<sub>2</sub> reaction in a dynamic reaction cell, which greatly improved the abundance sensitivity and allowed subfemtogram amounts of <sup>90</sup>Sr to be quantitatively imaged. The background equivalent concentration (BEC) was 0.14 ng g<sup>-1</sup> (equivalent to 7.0 × 10<sup>2</sup> Bq g<sup>-1</sup>) per data point, and the measurement time was within 1 s. Validation with CRMs and <sup>90</sup>Sr samples confirmed accuracy of 88-116% relative to reference values. The proposed system is a versatile platform that can be applied to the practical mapping of radioactive solids, which has broad implications for nuclear waste disposal, environmental remediation, and radiation protection.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-11-26
DOI
https://doi.org/10.1021/acs.analchem.5c05652
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Isotope-Specific Quantitative Mapping of 90 Sr at Subfemtogram Levels via Online Isotope Dilution and Laser Ablation Inductively Coupled Plasma Tandem Mass Spectrometry

Makoto Furukawa, Yoshitaka Takagai, Kayo Yanagisawa, Makoto Matsueda
Analytical Chemistry
Radioactive contamination and transfer
article

Isotope-Specific Quantitative Mapping of 90 Sr at Subfemtogram Levels via Online Isotope Dilution and Laser Ablation Inductively Coupled Plasma Tandem Mass Spectrometry

Makoto Furukawa, Yoshitaka Takagai, Kayo Yanagisawa, Makoto Matsueda
article en

Abstract

The quantitative mapping of radioisotopes in solids is crucial for understanding their microscale localization and migration. However, conventional radiometric and mass spectrometric techniques are only capable of bulk measurements without spatial resolution. Imaging plates provide spatial resolution, but they lack selectivity and cannot quantify radioisotopes that only emit beta radiation, such as <sup>90</sup>Sr. Here, the first system for isotope-specific quantitative mapping of a pure beta emitter is demonstrated, integrating online isotope dilution (ID) with laser ablation inductively coupled plasma tandem mass spectrometry (LA-ICP-MS/MS). In a case study, ultratrace levels of <sup>90</sup>Sr were accurately quantified without requiring matrix-matched certified reference materials (CRMs) for calibration or chemical separation. Severe isobaric/polyatomic interference (e.g., <sup>90</sup>Zr<sup>+</sup>, <sup>74</sup>Ge<sup>16</sup>O<sup>+</sup>, <sup>89</sup>Y<sup>1</sup>H<sup>+</sup>, and <sup>58</sup>Ni<sup>16</sup>O<sub>2</sub><sup>+</sup>) was efficiently suppressed by O<sub>2</sub> reaction in a dynamic reaction cell, which greatly improved the abundance sensitivity and allowed subfemtogram amounts of <sup>90</sup>Sr to be quantitatively imaged. The background equivalent concentration (BEC) was 0.14 ng g<sup>-1</sup> (equivalent to 7.0 × 10<sup>2</sup> Bq g<sup>-1</sup>) per data point, and the measurement time was within 1 s. Validation with CRMs and <sup>90</sup>Sr samples confirmed accuracy of 88-116% relative to reference values. The proposed system is a versatile platform that can be applied to the practical mapping of radioactive solids, which has broad implications for nuclear waste disposal, environmental remediation, and radiation protection.

Analytical ChemistryVol. 97(50)
Japan Atomic Energy Agency (JP), PerkinElmer (United States) (US), Fukushima University (JP)
Openalex Percentile: Top 66%
Radioactive contamination and transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.