Design and operational challenges of renewable-powered isolated microgrids: a zero-carbon approach

This article investigates the characteristics, operation and challenges of zero carbon microgrids, including size, generation from renewable sources, energy balance, and costs. An isolated zero-carbon microgrid is powered exclusively by renewable energy sources. It utilizes energy storage technologies, such as long-duration batteries or hydrogen storage, to mitigate intermittency and ensure a reliable power supply, allowing it to meet demand even under conditions of low production or high variability. The temporal variability between generation and load has technical and economic implications for microgrid sizing. This mismatch can be mitigated by combining renewable sources with diverse intermittency profiles, affecting both the storage system and the size of the generating units to be installed. This article formulates the sizing problem of an isolated microgrid designed to meet all load requirements solely through renewable sources and storage. The implications of this objective are analyzed and discussed, and sensitivity analysis studies are conducted to explore potential load shedding agreements and their impact on the solution. Solar, wind, and tidal energy exhibit a good degree of complementarity and help reduce storage requirements. However, the high cost of storage makes the oversizing of renewable sources even more attractive to ensure 100% load supply. On the other side, it was observed that allowing a load shedding of only 2.5% results in an approximate 46% reduction in the total system cost. Although the studies are carried out on a small microgrid, the conclusions can be expanded to systems of any size.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-25
DOI
https://doi.org/10.1038/s41598-025-28882-x
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and operational challenges of renewable-powered isolated microgrids: a zero-carbon approach

Pedro Bezerra Leite Neto, Denisson Q. Oliveira, Osvaldo R. Saavedra, Wender M. Figueredo
Scientific Reports
Microgrid Control and Optimization
article

Design and operational challenges of renewable-powered isolated microgrids: a zero-carbon approach

Pedro Bezerra Leite Neto, Denisson Q. Oliveira, Osvaldo R. Saavedra, Wender M. Figueredo
article en

Abstract

This article investigates the characteristics, operation and challenges of zero carbon microgrids, including size, generation from renewable sources, energy balance, and costs. An isolated zero-carbon microgrid is powered exclusively by renewable energy sources. It utilizes energy storage technologies, such as long-duration batteries or hydrogen storage, to mitigate intermittency and ensure a reliable power supply, allowing it to meet demand even under conditions of low production or high variability. The temporal variability between generation and load has technical and economic implications for microgrid sizing. This mismatch can be mitigated by combining renewable sources with diverse intermittency profiles, affecting both the storage system and the size of the generating units to be installed. This article formulates the sizing problem of an isolated microgrid designed to meet all load requirements solely through renewable sources and storage. The implications of this objective are analyzed and discussed, and sensitivity analysis studies are conducted to explore potential load shedding agreements and their impact on the solution. Solar, wind, and tidal energy exhibit a good degree of complementarity and help reduce storage requirements. However, the high cost of storage makes the oversizing of renewable sources even more attractive to ensure 100% load supply. On the other side, it was observed that allowing a load shedding of only 2.5% results in an approximate 46% reduction in the total system cost. Although the studies are carried out on a small microgrid, the conclusions can be expanded to systems of any size.

Scientific ReportsVol. 15(1)
Universidade Estadual de Campinas (UNICAMP) (BR), Universidade Federal do Maranhão (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa e ao Desenvolvimento Científico e Tecnológico do Maranhão
Openalex Percentile: Top 55%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.