Ultracompact SLSP sensor for rapid detection of grain moisture

In this work, we propose a methodology for grain moisture content detection based on a spoof localized surface plasmons (SLSPs) resonator, enabling highly efficient and precise quantification of moisture levels in grains. We conducted tests within the 0.9-1.1 GHz frequency range on nine wheat samples with varying moisture contents, successfully obtaining corresponding transmission spectra. Through calculation and in-depth analysis, a linear regression equation for wheat moisture content was established, with a coefficient of determination (R<sup>2</sup>) as high as 0.985. Experimental data indicated that the root mean square error (RMSE), mean absolute error (MAE), and maximum relative error (MRE) of predicted values were 0.321%, 0.24%, and 7.6%, respectively.

Authors

Publication Details

Journal
Optics Express
Published
2025-11-25
DOI
https://doi.org/10.1364/oe.576294
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultracompact SLSP sensor for rapid detection of grain moisture

Chengxin Cai, Sheng-Fan Yang, Mingxing Li, Jingrui Li et al.
Optics Express
Microwave and Dielectric Measurement Techniques
article

Ultracompact SLSP sensor for rapid detection of grain moisture

Chengxin Cai, Sheng-Fan Yang, Mingxing Li, Jingrui Li, Yuhang Yin, Yangyang Zhou
article en

Abstract

In this work, we propose a methodology for grain moisture content detection based on a spoof localized surface plasmons (SLSPs) resonator, enabling highly efficient and precise quantification of moisture levels in grains. We conducted tests within the 0.9-1.1 GHz frequency range on nine wheat samples with varying moisture contents, successfully obtaining corresponding transmission spectra. Through calculation and in-depth analysis, a linear regression equation for wheat moisture content was established, with a coefficient of determination (R<sup>2</sup>) as high as 0.985. Experimental data indicated that the root mean square error (RMSE), mean absolute error (MAE), and maximum relative error (MRE) of predicted values were 0.321%, 0.24%, and 7.6%, respectively.

Optics ExpressVol. 33(25)
Openalex Percentile: Top 64%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.