Evaluating Climate Change Adaptation in Vernacular Dwellings: Thermal Comfort and Ventilation of Yikeyin in Haiyan Village, Kunming

In response to global climate change, harnessing the climate-adaptive wisdom of vernacular dwellings is crucial for sustainable architectural design. This study takes Haiyan Village in the Kunming plateau area as a case study, focusing on three typical vernacular dwelling types of Yikeyin—‘Half seal’, ‘One seal’, and ‘Two seals’. Using Ladybug and Honeybee within the Rhino Grasshopper platform, a quantitative comparative analysis was conducted to evaluate their natural ventilation efficiency (characterized by Air Changes per Hour, ACH) and indoor thermal comfort (characterized by Predicted Mean Vote, PMV, and Predicted Percentage of Dissatisfaction, PPD). The results indicate the following: (1) Throughout the year, the ‘Two seals’ dwelling type exhibits the most stable diurnal temperature variation, while the ‘Half seal’ dwelling type shows the greatest fluctuation in its diurnal temperature range. (2) The summer ACH values for ‘Half seal’, ‘One seal’, and ‘Two seals’ dwelling types are 3.8~4.5, 1.5~2.9, and 0.8~1.6, while the winter values are 1.9~2.6, 1.3~1.8, and 0.7~1.0. The ventilation efficiency in summer is generally higher than that in winter, and it shows a significant decreasing trend as building volume increases. (3) The summer PPD values for ‘Half seal’, ‘One seal’, and ‘Two seals’ dwelling types are 12%, 18%, and 35%, while the winter values are 22%, 15%, and 12%. (4) The ‘One seal’ dwelling type exhibits good ventilation and thermal comfort throughout the year. The ‘Half seal’ demonstrates the best ventilation and thermal comfort in summer but poorer thermal comfort in winter. The ‘Two seals‘ dwelling type achieves the best thermal comfort in winter, but lower ventilation efficiency, while in summer, both thermal comfort and ventilation are poor. This study not only addresses the gap in the quantitative assessment of climate adaptability in vernacular dwellings but also provides critical data support and a theoretical basis for the scientific preservation, adaptive renewal, and sustainable inheritance of vernacular architecture in the context of climate change.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-11-24
DOI
https://doi.org/10.3390/su172310531
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Climate Change Adaptation in Vernacular Dwellings: Thermal Comfort and Ventilation of Yikeyin in Haiyan Village, Kunming

Xinying Guan, Tao Fu, Jingyi Ye, Yaoning Yang et al.
Sustainability
Building Energy and Comfort Optimization
article

Evaluating Climate Change Adaptation in Vernacular Dwellings: Thermal Comfort and Ventilation of Yikeyin in Haiyan Village, Kunming

Xinying Guan, Tao Fu, Jingyi Ye, Yaoning Yang, Yingli Zhu, Shihua Li, Yaqi Chen
article en

Abstract

In response to global climate change, harnessing the climate-adaptive wisdom of vernacular dwellings is crucial for sustainable architectural design. This study takes Haiyan Village in the Kunming plateau area as a case study, focusing on three typical vernacular dwelling types of Yikeyin—‘Half seal’, ‘One seal’, and ‘Two seals’. Using Ladybug and Honeybee within the Rhino Grasshopper platform, a quantitative comparative analysis was conducted to evaluate their natural ventilation efficiency (characterized by Air Changes per Hour, ACH) and indoor thermal comfort (characterized by Predicted Mean Vote, PMV, and Predicted Percentage of Dissatisfaction, PPD). The results indicate the following: (1) Throughout the year, the ‘Two seals’ dwelling type exhibits the most stable diurnal temperature variation, while the ‘Half seal’ dwelling type shows the greatest fluctuation in its diurnal temperature range. (2) The summer ACH values for ‘Half seal’, ‘One seal’, and ‘Two seals’ dwelling types are 3.8~4.5, 1.5~2.9, and 0.8~1.6, while the winter values are 1.9~2.6, 1.3~1.8, and 0.7~1.0. The ventilation efficiency in summer is generally higher than that in winter, and it shows a significant decreasing trend as building volume increases. (3) The summer PPD values for ‘Half seal’, ‘One seal’, and ‘Two seals’ dwelling types are 12%, 18%, and 35%, while the winter values are 22%, 15%, and 12%. (4) The ‘One seal’ dwelling type exhibits good ventilation and thermal comfort throughout the year. The ‘Half seal’ demonstrates the best ventilation and thermal comfort in summer but poorer thermal comfort in winter. The ‘Two seals‘ dwelling type achieves the best thermal comfort in winter, but lower ventilation efficiency, while in summer, both thermal comfort and ventilation are poor. This study not only addresses the gap in the quantitative assessment of climate adaptability in vernacular dwellings but also provides critical data support and a theoretical basis for the scientific preservation, adaptive renewal, and sustainable inheritance of vernacular architecture in the context of climate change.

SustainabilityVol. 17(23)
Yunnan University (CN), Yunnan Population and Family Planning Research Institute (CN)
Openalex Percentile: Top 61%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.