Hyaluronic Acid-Coated Solid Lipid Nanoparticles-Functionalized Quartz-Crystal Microbalance (QCM) Immunosensor for Label-Free Haptoglobin Detection: Toward Monitoring of Neuroinflammation

Neurodegenerative diseases (NDs) have distinct molecular mechanisms but share pathological hallmarks, such as dopaminergic neuron degeneration, cognitive decline, and neuroinflammation. These are strongly linked to chronic inflammation and oxidative stress, associated with elevated levels of systemic biomarkers, such as haptoglobin (Hp), an acute-phase inflammatory glycoprotein. However, current Hp detection methods are costly, time-consuming, and insufficiently sensitive, while ND biomarkers require highly invasive cerebrospinal fluid (CSF) sampling. To overcome these limitations, we developed the first quartz-crystal microbalance (QCM)-based immunobiosensor for rapid quantification of human Hp in human serum, offering a less invasive alternative. The system employs a custom QCM-R device for high-resolution frequency/resistance measurements. Fabrication included functionalization of the quartz surface with a thiolated polyethylene glycol amine self-assembled monolayer, followed by immobilization of hyaluronic acid-coated solid lipid nanoparticles (HA-SLNs)─used here for the first time─and covalent attachment of Hp antibodies. The biosensor showed robust performance with high sensitivity (612.10 ± 28.14 μg mL<sup>-1</sup>), reproducibility (average coefficient of variation, CV<sub>av</sub>% = 0.50%), selectivity, and excellent limits of detection (0.063 ± 0.003 μg mL<sup>-1</sup>) and quantification (0.21 ± 0.01 μg mL<sup>-1</sup>). Surface modifications were validated via time-of-flight secondary ion mass spectrometry (ToF-SIMS), atomic force microscopy (AFM), and electrochemical impedance spectroscopy (EIS). This platform offers a cost-effective, user-friendly alternative for the monitoring of neuroinflammation associated with ND progression by eliminating the need for CSF sampling.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-11-10
DOI
https://doi.org/10.1021/acs.analchem.5c05079
Citations
2
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hyaluronic Acid-Coated Solid Lipid Nanoparticles-Functionalized Quartz-Crystal Microbalance (QCM) Immunosensor for Label-Free Haptoglobin Detection: Toward Monitoring of Neuroinflammation

Marco Consumi, Elia Landi, Valerio Vignoli, Ilaria Clemente et al.
2 citations
Analytical Chemistry
Acoustic Wave Resonator Technologies
1.35
article

Hyaluronic Acid-Coated Solid Lipid Nanoparticles-Functionalized Quartz-Crystal Microbalance (QCM) Immunosensor for Label-Free Haptoglobin Detection: Toward Monitoring of Neuroinflammation

Marco Consumi, Elia Landi, Valerio Vignoli, Ilaria Clemente, Ada Fort, Luigi Talarico, Agnese Magnani, Simone Pepi, Gabriella Tamasi, Mariagrazia Lettieri, Giulia Gabbricci
article en
2 citations

Abstract

Neurodegenerative diseases (NDs) have distinct molecular mechanisms but share pathological hallmarks, such as dopaminergic neuron degeneration, cognitive decline, and neuroinflammation. These are strongly linked to chronic inflammation and oxidative stress, associated with elevated levels of systemic biomarkers, such as haptoglobin (Hp), an acute-phase inflammatory glycoprotein. However, current Hp detection methods are costly, time-consuming, and insufficiently sensitive, while ND biomarkers require highly invasive cerebrospinal fluid (CSF) sampling. To overcome these limitations, we developed the first quartz-crystal microbalance (QCM)-based immunobiosensor for rapid quantification of human Hp in human serum, offering a less invasive alternative. The system employs a custom QCM-R device for high-resolution frequency/resistance measurements. Fabrication included functionalization of the quartz surface with a thiolated polyethylene glycol amine self-assembled monolayer, followed by immobilization of hyaluronic acid-coated solid lipid nanoparticles (HA-SLNs)─used here for the first time─and covalent attachment of Hp antibodies. The biosensor showed robust performance with high sensitivity (612.10 ± 28.14 μg mL<sup>-1</sup>), reproducibility (average coefficient of variation, CV<sub>av</sub>% = 0.50%), selectivity, and excellent limits of detection (0.063 ± 0.003 μg mL<sup>-1</sup>) and quantification (0.21 ± 0.01 μg mL<sup>-1</sup>). Surface modifications were validated via time-of-flight secondary ion mass spectrometry (ToF-SIMS), atomic force microscopy (AFM), and electrochemical impedance spectroscopy (EIS). This platform offers a cost-effective, user-friendly alternative for the monitoring of neuroinflammation associated with ND progression by eliminating the need for CSF sampling.

Analytical ChemistryVol. 97(46)
University of Siena (IT)
Openalex Percentile: Top 17%
Acoustic Wave Resonator Technologies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.