Species-Specific Isotope Dilution Methodology for the SI Traceable Quantification of Serum Human Ferritin Light Chain (FTL)

There is an urgent need for reference methodologies to assign SI traceable values to quality control (QC) materials for protein biomarkers to validate biochemical tests currently used in disease diagnosis and patient-specific therapeutics. Here we describe a novel methodology specifically developed for the SI traceable quantification of human serum ferritin light chain (FTL), an established biomarker for the diagnosis of iron-related disorders such as hemochromatosis. Natural and <sup>34</sup>S isotopically enriched human FTL standards were recombinantly expressed using the HEK-293 mammalian cell system. Both standards were fully characterized for their total sulfur content, isotopic abundance, species distribution and primary sequence before using them for isotope dilution analysis (IDA). Treatment of serum spiked with FTL was optimized to selectively remove high abundant serum proteins without affecting significantly the integrity of the FTL. This was achieved by using methanol protein precipitation in combination with heat treatment and ultrafiltration. Complementary asymmetrical field-flow-fractionation (AF4) and anion-exchange high performance liquid chromatography (AE-HPLC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) were used to monitor the impact of sample treatment on protein removal and FTL recovery. Both standards, natural and enriched, were used with the optimal sample treatment in a double species-specific isotope dilution analysis (SS-IDA) workflow for the determination of FTL in the WHO "4th International Standard for Ferritin" (NIBSC 19/118) resulting in a protein mass fraction of 11.0 with an expanded uncertainty (U, <i>k</i> = 2) of 1.0 μg mL<sup>-1</sup> (RSU of 9.4%). The method was validated by standard addition experiments, and a full uncertainty budget was established. For the first time sulfur SS-IDA has been used to assign an SI traceable value to a relatively low abundance serum protein biomarker at supraphysiological concentrations in a WHO standard. This methodology will be invaluable for adding SI traceability to existing QC materials and for the certification of new biomarker reference materials.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-11-13
DOI
https://doi.org/10.1021/acs.analchem.5c04597
Primary Topic
Iron Metabolism and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Species-Specific Isotope Dilution Methodology for the SI Traceable Quantification of Serum Human Ferritin Light Chain (FTL)

Heidi Goenaga‐Infante, B. Fox, Luise Luckau, Christian Ward-Deitrich et al.
Analytical Chemistry
Iron Metabolism and Disorders
article

Species-Specific Isotope Dilution Methodology for the SI Traceable Quantification of Serum Human Ferritin Light Chain (FTL)

Heidi Goenaga‐Infante, B. Fox, Luise Luckau, Christian Ward-Deitrich, Sarah Hill, M. Estela del Castillo Busto, Sachin Vilas Nehete, Forbes W. Robertson, Holger Hannemann
article en

Abstract

There is an urgent need for reference methodologies to assign SI traceable values to quality control (QC) materials for protein biomarkers to validate biochemical tests currently used in disease diagnosis and patient-specific therapeutics. Here we describe a novel methodology specifically developed for the SI traceable quantification of human serum ferritin light chain (FTL), an established biomarker for the diagnosis of iron-related disorders such as hemochromatosis. Natural and <sup>34</sup>S isotopically enriched human FTL standards were recombinantly expressed using the HEK-293 mammalian cell system. Both standards were fully characterized for their total sulfur content, isotopic abundance, species distribution and primary sequence before using them for isotope dilution analysis (IDA). Treatment of serum spiked with FTL was optimized to selectively remove high abundant serum proteins without affecting significantly the integrity of the FTL. This was achieved by using methanol protein precipitation in combination with heat treatment and ultrafiltration. Complementary asymmetrical field-flow-fractionation (AF4) and anion-exchange high performance liquid chromatography (AE-HPLC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) were used to monitor the impact of sample treatment on protein removal and FTL recovery. Both standards, natural and enriched, were used with the optimal sample treatment in a double species-specific isotope dilution analysis (SS-IDA) workflow for the determination of FTL in the WHO "4th International Standard for Ferritin" (NIBSC 19/118) resulting in a protein mass fraction of 11.0 with an expanded uncertainty (U, <i>k</i> = 2) of 1.0 μg mL<sup>-1</sup> (RSU of 9.4%). The method was validated by standard addition experiments, and a full uncertainty budget was established. For the first time sulfur SS-IDA has been used to assign an SI traceable value to a relatively low abundance serum protein biomarker at supraphysiological concentrations in a WHO standard. This methodology will be invaluable for adding SI traceability to existing QC materials and for the certification of new biomarker reference materials.

Analytical ChemistryVol. 97(46)
Whiteley Clinic (GB), Science Oxford (GB), National Institute for Biological Standards and Control (GB)
Openalex Percentile: Top 52%
Iron Metabolism and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.