High sensitivity and Figure of Merit Achieved in a WS <sub>2</sub> /Au-SPR Microfluidic Sensing Chip for Glucose Detection

A high-performance surface plasmon resonance (SPR) biosensor for glucose detection was developed based on a planar waveguide. The deposition of tungsten disulfide (WS<sub>2</sub>) nanoparticles onto a gold film significantly enhanced the refractive index sensitivity, reaching 2530.1 nm/RIU, while the figure of merit (FoM) was remarkably improved from 34.3 to 53.3 RIU<sup>-1</sup> by enhancing the evanescent field intensity in the sensing region through precise modulation of the waveguide thickness. A biorecognition interface was constructed via self-assembly of 11-mercaptoundecanoic acid (11-MUA) to enable stable and efficient immobilization of glucose oxidase, facilitating highly sensitive glucose detection. The resonance wavelength exhibited excellent linear correlation with glucose concentration, achieving a sensitivity of 91.1 pm/(μg/mL) within the concentration range of 0-150 μg/mL. The sensor demonstrated high specificity and operational stability for glucose detection, as confirmed by analytical validation.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-11-12
DOI
https://doi.org/10.1021/acs.langmuir.5c04180
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High sensitivity and Figure of Merit Achieved in a WS 2 /Au-SPR Microfluidic Sensing Chip for Glucose Detection

Wenlong Yang, Rui Pan, Chenwei Wang, Liuyang Zhang et al.
2 citations
Langmuir
Advanced biosensing and bioanalysis techniques
1.61
article

High sensitivity and Figure of Merit Achieved in a WS 2 /Au-SPR Microfluidic Sensing Chip for Glucose Detection

Wenlong Yang, Rui Pan, Chenwei Wang, Liuyang Zhang, Yu Wang
article en
2 citations

Abstract

A high-performance surface plasmon resonance (SPR) biosensor for glucose detection was developed based on a planar waveguide. The deposition of tungsten disulfide (WS<sub>2</sub>) nanoparticles onto a gold film significantly enhanced the refractive index sensitivity, reaching 2530.1 nm/RIU, while the figure of merit (FoM) was remarkably improved from 34.3 to 53.3 RIU<sup>-1</sup> by enhancing the evanescent field intensity in the sensing region through precise modulation of the waveguide thickness. A biorecognition interface was constructed via self-assembly of 11-mercaptoundecanoic acid (11-MUA) to enable stable and efficient immobilization of glucose oxidase, facilitating highly sensitive glucose detection. The resonance wavelength exhibited excellent linear correlation with glucose concentration, achieving a sensitivity of 91.1 pm/(μg/mL) within the concentration range of 0-150 μg/mL. The sensor demonstrated high specificity and operational stability for glucose detection, as confirmed by analytical validation.

LangmuirVol. 41(46)
Harbin University of Science and Technology (CN), Advanced Laser Technology (United Kingdom) (GB)
Openalex Percentile: Top 14%
Advanced biosensing and bioanalysis techniques
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.