Measurement of <sup>227</sup> Ac by Isotopic Ratio with <sup>225</sup> Ac Using ICP-MS
A method is reported for the measurement of <sup>227</sup>Ac using inductively coupled plasma mass spectrometry (ICP-MS) and isotope ratio analysis. The method has application for the quality testing of <sup>225</sup>Ac produced as an active pharmaceutical ingredient (API). The <sup>225</sup>Ac/<sup>227</sup>Ac isotope ratio is measured directly from ICP-MS count rate data and converted to an <sup>225</sup>Ac/<sup>227</sup>Ac activity ratio by using basic nuclear decay equations. The activity ratio, which is itself a measure of radioisotopic purity, is coupled with an orthogonal measurement of <sup>225</sup>Ac activity to obtain an absolute <sup>227</sup>Ac activity. Thus, the method may be used to report the <sup>227</sup>Ac content of an <sup>225</sup>Ac API in absolute or relative terms. The methodology was evaluated against appropriate validation criteria (e.g., linearity, accuracy, precision, specificity) by analyzing a series of solutions containing known quantities of <sup>225</sup>Ac and <sup>227</sup>Ac. Accuracy was evaluated using a spike recovery study. The spike recoveries were 100-108% for samples with 0.100 to 2.00 ng L<sup>-1</sup> of <sup>227</sup>Ac and 74-91% for 0.025 ng L<sup>-1</sup> of <sup>227</sup>Ac. Intermediate precision was measured as 4.1% using replicate measurements (<i>n</i> = 12, two instruments) of <sup>227</sup>Ac spiked samples (0.5 ng L<sup>-1</sup>). The instrumental detection limits for <sup>227</sup>Ac were shown to be as low as 23 Bq L<sup>-1</sup> (0.0086 ng L<sup>-1</sup>), which is lower than comparable methods for the quantification of <sup>227</sup>Ac in <sup>225</sup>Ac APIs. Actinium-225 samples are analyzed under this method without any need for <sup>225</sup>Ac decay or <sup>227</sup>Ac daughter in-growth. Sample preparation involves simple dilution of the <sup>225</sup>Ac API in 3% HCl/1% HNO<sub>3</sub>. The analysis takes as little as 2 h using equipment common to radioanalytical laboratories. Thus, the measurement of <sup>227</sup>Ac by this method can be performed as part of routine <sup>225</sup>Ac API quality testing and reported on release documents. This is a significant advantage over radiometric methods reported for the quantification of <sup>227</sup>Ac in <sup>225</sup>Ac APIs, which require days to weeks before reportable results can be obtained. The measurement of <sup>227</sup>Ac by ICP-MS and isotope ratio analysis is rapid, accurate, and sensitive. The implementation of this method for <sup>225</sup>Ac API quality testing will help <sup>225</sup>Ac producers and end-users ensure product quality and demonstrate regulatory compliance.
Authors
- Cory A. Hawkins (ORCID: https://orcid.org/0000-0002-3132-1398)
- D.J. de Vries
- Jakob E. Baumeister (ORCID: https://orcid.org/0009-0000-6692-4204)
- John W. N. Brown (ORCID: https://orcid.org/0000-0001-9719-8137)
- Joshua B. McCormick (ORCID: https://orcid.org/0000-0003-2207-5858)
- Miguel Toro-González (ORCID: https://orcid.org/0000-0003-3320-423X)
- Benjamin W. Puffer
Institutions
- Japan Radioisotope Association (JP)
Publication Details
- Journal
- ACS Omega
- Published
- 2025-11-11
- DOI
- https://doi.org/10.1021/acsomega.5c09343
- Citations
- 1
- Primary Topic
- Radiopharmaceutical Chemistry and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.36