Comparison of High-Frequency Circular Array Imaging Algorithms for Intravascular Ultrasound Imaging Simulations

A circular array transducer with high frequency and small aperture size is highly desired for intravascular ultrasound (IVUS) imaging application. With the breakthrough of array transducer techniques, high-frequency circular array transducers with the advantages of high frame rate and high resolution have been developed and manufactured. Focusing on the development of a matched high-frequency imaging algorithms, this study introduces apodization functions into 55 MHz circular-array IVUS imaging, proposes a circular-array-specific apodization model, and breaks the lateral-resolution limit inherent to conventional delay-and-sum (DAS) beamforming. In the study, three typical algorithms—synthetic aperture (SA), apodized synthetic aperture (ASA), and sparse synthetic aperture (SSA)—are investigated in order to well achieve an effective imaging result for our newly derived circular array transducer with 55 MHz. In the scatterer’s simulation, at a depth of 1.5 mm, the ASA algorithm improves the lateral resolution from 260 μm for conventional SA to 175 μm (a 33% enhancement), while tripling the frame rate. Meanwhile, SSA maintains a resolution of 300 μm and reduces the data volume by 50%, laying the groundwork for real-time 3D imaging. Further phantom imaging testing shows that the SA algorithm has the best imaging effect on regional defects. The ASA algorithm has the best imaging effect on point defects while improving the imaging frame rate. This study provides insights and a foundation for optimizing circular-array intravascular ultrasound imaging, the proposed ASA model can be directly ported to existing 40–60 MHz circular-array IVUS systems, offering a new route for accurate early-plaque identification.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-11-25
DOI
https://doi.org/10.3390/electronics14234623
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of High-Frequency Circular Array Imaging Algorithms for Intravascular Ultrasound Imaging Simulations

Mang I Vai, Wei–Ting Liu, Kanjie Du, Zhiqing Zhang et al.
Electronics
Ultrasound Imaging and Elastography
article

Comparison of High-Frequency Circular Array Imaging Algorithms for Intravascular Ultrasound Imaging Simulations

Mang I Vai, Wei–Ting Liu, Kanjie Du, Zhiqing Zhang, Qingqing Ke
article en

Abstract

A circular array transducer with high frequency and small aperture size is highly desired for intravascular ultrasound (IVUS) imaging application. With the breakthrough of array transducer techniques, high-frequency circular array transducers with the advantages of high frame rate and high resolution have been developed and manufactured. Focusing on the development of a matched high-frequency imaging algorithms, this study introduces apodization functions into 55 MHz circular-array IVUS imaging, proposes a circular-array-specific apodization model, and breaks the lateral-resolution limit inherent to conventional delay-and-sum (DAS) beamforming. In the study, three typical algorithms—synthetic aperture (SA), apodized synthetic aperture (ASA), and sparse synthetic aperture (SSA)—are investigated in order to well achieve an effective imaging result for our newly derived circular array transducer with 55 MHz. In the scatterer’s simulation, at a depth of 1.5 mm, the ASA algorithm improves the lateral resolution from 260 μm for conventional SA to 175 μm (a 33% enhancement), while tripling the frame rate. Meanwhile, SSA maintains a resolution of 300 μm and reduces the data volume by 50%, laying the groundwork for real-time 3D imaging. Further phantom imaging testing shows that the SA algorithm has the best imaging effect on regional defects. The ASA algorithm has the best imaging effect on point defects while improving the imaging frame rate. This study provides insights and a foundation for optimizing circular-array intravascular ultrasound imaging, the proposed ASA model can be directly ported to existing 40–60 MHz circular-array IVUS systems, offering a new route for accurate early-plaque identification.

ElectronicsVol. 14(23)
Sun Yat-sen University (CN), University of Macau (MO), Zhuhai Institute of Advanced Technology (CN)
Openalex Percentile: Top 49%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.