Incidence and predictors of difficult videolaryngoscopy using a hyperangulated device in elective surgical patients: a prospective cohort study in China

While the utilization of video laryngoscope has become increasingly prevalent, the incidence of difficult videolaryngoscopy and its associated factors remain largely undefined. Therefore, this study was undertaken to determine the incidence of difficult videolaryngoscopy using a hyperangulated device, and to identify associated factors, specifically within a cohort of elective surgical patients in China presenting with normal airway anatomy. This study was a prospective cohort investigation that included 4,902 adult patients who underwent single-lumen tracheal intubation using a video laryngoscope. Data encompassing participants’ demographic characteristics, preoperative airway assessments, and intubation procedure details were systematically collected. Patients were categorized into two groups based on the Cormack-Lehane classification, with difficult videolaryngoscopy defined as a Cormack-Lehane grade of ≥ 3. The incidence of difficult videolaryngoscopy was documented. Subsequently, logistic regression analysis was performed to investigate factors associated with its occurrence. The findings indicated that the incidence of difficult videolaryngoscopy was 2.1%. Multivariate logistic regression analysis demonstrated a statistically significant effect of interincisor distance on the incidence of difficult videolaryngoscopy (OR = 0.669, 95% CI = 0.490–0.913, P = 0.011). Additionally, a statistically significant association was found between Mallampati grade III-IV and difficult videolaryngoscopy (Mallampati grade III: OR = 3.200, 95% CI = 1.813–5.650, P < 0.001; Mallampati grade IV: OR = 2.899, 95% CI = 1.567–5.361, P = 0.001). The incidence of difficult videolaryngoscopy was 2.1% in this cohort when using a hyperangulated videolaryngoscope. The interincisor distance and Mallampati grades (III and IV) are independently predictors for difficult videolaryngoscopy with this blade type. www.chictr.org.cn/ . Identifier ChiCTR220058009, 26 March 2022.

Authors

Institutions

Publication Details

Journal
BMC Anesthesiology
Published
2025-11-25
DOI
https://doi.org/10.1186/s12871-025-03496-y
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incidence and predictors of difficult videolaryngoscopy using a hyperangulated device in elective surgical patients: a prospective cohort study in China

Hailong Bing, Qinjun Chu, Jianjun Yang, Liumei Li et al.
BMC Anesthesiology
Airway Management and Intubation Techniques
article

Incidence and predictors of difficult videolaryngoscopy using a hyperangulated device in elective surgical patients: a prospective cohort study in China

Hailong Bing, Qinjun Chu, Jianjun Yang, Liumei Li, Hongwei Wang, Guanyu Yang, Zeping Li, Yili Zhao
article en

Abstract

While the utilization of video laryngoscope has become increasingly prevalent, the incidence of difficult videolaryngoscopy and its associated factors remain largely undefined. Therefore, this study was undertaken to determine the incidence of difficult videolaryngoscopy using a hyperangulated device, and to identify associated factors, specifically within a cohort of elective surgical patients in China presenting with normal airway anatomy. This study was a prospective cohort investigation that included 4,902 adult patients who underwent single-lumen tracheal intubation using a video laryngoscope. Data encompassing participants’ demographic characteristics, preoperative airway assessments, and intubation procedure details were systematically collected. Patients were categorized into two groups based on the Cormack-Lehane classification, with difficult videolaryngoscopy defined as a Cormack-Lehane grade of ≥ 3. The incidence of difficult videolaryngoscopy was documented. Subsequently, logistic regression analysis was performed to investigate factors associated with its occurrence. The findings indicated that the incidence of difficult videolaryngoscopy was 2.1%. Multivariate logistic regression analysis demonstrated a statistically significant effect of interincisor distance on the incidence of difficult videolaryngoscopy (OR = 0.669, 95% CI = 0.490–0.913, P = 0.011). Additionally, a statistically significant association was found between Mallampati grade III-IV and difficult videolaryngoscopy (Mallampati grade III: OR = 3.200, 95% CI = 1.813–5.650, P < 0.001; Mallampati grade IV: OR = 2.899, 95% CI = 1.567–5.361, P = 0.001). The incidence of difficult videolaryngoscopy was 2.1% in this cohort when using a hyperangulated videolaryngoscope. The interincisor distance and Mallampati grades (III and IV) are independently predictors for difficult videolaryngoscopy with this blade type. www.chictr.org.cn/ . Identifier ChiCTR220058009, 26 March 2022.

BMC AnesthesiologyVol. 25(1)
Zhengzhou Central Hospital (CN), First Affiliated Hospital of Zhengzhou University (CN)
Openalex Percentile: Top 45%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.