Monitoring Inhibition of Hemoglobin Peroxidase Activity After Exposure to Cigarette Smoke Using an Electrochemical Biosensor

This work presents a catalysis-based electrochemical biosensor to evaluate the peroxidase-like activity of methemoglobin (Hb-PLA) after exposure to cigarette smoke (CS) at different time intervals. The system consists of a microelectrode array coupled with a PDMS chamber containing a methemoglobin solution (biorecognition element). Hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) acts as the substrate, while 3,3',5,5'-tetramethylbenzidine (TMB) functions as the chromogenic substrate for the Hb-PLA through its oxidation reaction. A spectrophotometric technique is used as a reference method to assess the catalytic activity of methemoglobin. Positive control samples exhibited higher absorbance, indicating strong catalytic activity, whereas CS-exposed samples showed a marked reduction, which was confirmed by the negative control. Cyclic voltammetry revealed significant alterations in the oxidation and reduction peaks of the CS-exposed samples. Therefore, chronoamperometry was employed to quantify the charge transfer as the electrochemical response associated with Hb-PLA, yielding a sensitivity of 0.86 ± 0.06 (%Hb-PLA/mC) and a limit of detection (LOD) of 0.23 (mC). The results demonstrate that cigarette smoke impairs the Hb-PLA in a time-dependent manner, with longer exposure reducing the activity by up to 25%. The proposed biosensor provides a rapid, sensitive, and straightforward strategy for detecting functional alterations in solutions of methemoglobin induced by environmental pollutants such as cigarette smoke.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-11-25
DOI
https://doi.org/10.3390/bios15120767
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring Inhibition of Hemoglobin Peroxidase Activity After Exposure to Cigarette Smoke Using an Electrochemical Biosensor

Ana Marı́a Espinosa, Celia Sánchez‐Pérez, José Antonio García-García, Flor Cortés-Ortegón et al.
Biosensors
Electrochemical sensors and biosensors
article

Monitoring Inhibition of Hemoglobin Peroxidase Activity After Exposure to Cigarette Smoke Using an Electrochemical Biosensor

Ana Marı́a Espinosa, Celia Sánchez‐Pérez, José Antonio García-García, Flor Cortés-Ortegón, Alfonso Sequeda-Juárez, Diego Ortega-Picazo
article en

Abstract

This work presents a catalysis-based electrochemical biosensor to evaluate the peroxidase-like activity of methemoglobin (Hb-PLA) after exposure to cigarette smoke (CS) at different time intervals. The system consists of a microelectrode array coupled with a PDMS chamber containing a methemoglobin solution (biorecognition element). Hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) acts as the substrate, while 3,3',5,5'-tetramethylbenzidine (TMB) functions as the chromogenic substrate for the Hb-PLA through its oxidation reaction. A spectrophotometric technique is used as a reference method to assess the catalytic activity of methemoglobin. Positive control samples exhibited higher absorbance, indicating strong catalytic activity, whereas CS-exposed samples showed a marked reduction, which was confirmed by the negative control. Cyclic voltammetry revealed significant alterations in the oxidation and reduction peaks of the CS-exposed samples. Therefore, chronoamperometry was employed to quantify the charge transfer as the electrochemical response associated with Hb-PLA, yielding a sensitivity of 0.86 ± 0.06 (%Hb-PLA/mC) and a limit of detection (LOD) of 0.23 (mC). The results demonstrate that cigarette smoke impairs the Hb-PLA in a time-dependent manner, with longer exposure reducing the activity by up to 25%. The proposed biosensor provides a rapid, sensitive, and straightforward strategy for detecting functional alterations in solutions of methemoglobin induced by environmental pollutants such as cigarette smoke.

BiosensorsVol. 15(12)
Hospital General de México (MX), Universidad Nacional Autónoma de México (MX)
Secretaría de Estado de Ciencia, Tecnología e Innovación
Openalex Percentile: Top 64%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.