Automating IMRT planning for cervical cancer using dimension-scaled prior-based Vanilla Bayesian optimization

<i>Objective.</i>Manual inverse planning for radiation therapy is labor-intensive and often prone to inconsistent plan quality due to multiple adjustable planning hyperparameters, varying planner experience, and differing time constraints. Automated treatment planning offers a solution to these challenges. The present study investigates the effectiveness of dimension-scaled prior (DSP) Vanilla Bayesian optimization (BO) with a log-expected improvement (logEI) acquisition function in automating intensity-modulated radiation therapy (IMRT) planning for cancer cervix (CaCx) in high-dimensional settings.<i>Approach.</i>A Python-based auto-optimization script utilizing DSP Vanilla BO with logEI was employed to iteratively optimize the planning hyperparameters, including dose objectives and their corresponding weights for CaCx case IMRT plans on the Varian Eclipse treatment planning system (TPS) v18.0. This approach was assessed in 30 retrospectively selected pelvic node-positive CaCx cases, and the dosimetric parameters, based on EMBRACE-II protocol, were compared with plans generated from manual, Sparse Axis-Aligned Subspace BO (SAASBO), and stopping criterion-based DSP Vanilla BO.<i>Main results.</i>DSP Vanilla BO plans demonstrated superior dose conformity (CI95%PTV45&CI80%PTV45) and organs at risk (OAR) sparing (V40GyBowel,V30GyBowel,V40GyBladder,V40GyRectum,D0.01%femoral heads,Dmeanfemoral heads, andDmeankidneys) compared to manual planning with significant improvements (<i>p</i>< 0.05), while maintaining adequate clinical target coverage for CTV<sub>N</sub>, PTV<sub>55</sub>, ITV<sub>45</sub>, and PTV<sub>45</sub>. Compared to SAASBO, DSP Vanilla BO achieved comparable dosimetric quality but with less computation time (∼94 vs 360 min). The addition of stopping criteria further reduced the optimization time to ∼44 min while maintaining a plan quality comparable to manual planning.<i>Significance.</i>The study demonstrated that DSP Vanilla BO automated plans achieved comparable target coverage, with an improvement in OAR sparing, compared to manual plans. This highlights its effectiveness as an efficient, data-independent method for automating IMRT planning, which can be easily integrated into a TPS and benefit clinics with limited resources.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-11-25
DOI
https://doi.org/10.1088/1361-6560/ae2419
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automating IMRT planning for cervical cancer using dimension-scaled prior-based Vanilla Bayesian optimization

Abhishek Shinghal, Shrabani Barman, Satyajit Pradhan, Neeraj Sharma et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

Automating IMRT planning for cervical cancer using dimension-scaled prior-based Vanilla Bayesian optimization

Abhishek Shinghal, Shrabani Barman, Satyajit Pradhan, Neeraj Sharma, Vinay Saini, Ankita Rungta Kapoor
article en

Abstract

<i>Objective.</i>Manual inverse planning for radiation therapy is labor-intensive and often prone to inconsistent plan quality due to multiple adjustable planning hyperparameters, varying planner experience, and differing time constraints. Automated treatment planning offers a solution to these challenges. The present study investigates the effectiveness of dimension-scaled prior (DSP) Vanilla Bayesian optimization (BO) with a log-expected improvement (logEI) acquisition function in automating intensity-modulated radiation therapy (IMRT) planning for cancer cervix (CaCx) in high-dimensional settings.<i>Approach.</i>A Python-based auto-optimization script utilizing DSP Vanilla BO with logEI was employed to iteratively optimize the planning hyperparameters, including dose objectives and their corresponding weights for CaCx case IMRT plans on the Varian Eclipse treatment planning system (TPS) v18.0. This approach was assessed in 30 retrospectively selected pelvic node-positive CaCx cases, and the dosimetric parameters, based on EMBRACE-II protocol, were compared with plans generated from manual, Sparse Axis-Aligned Subspace BO (SAASBO), and stopping criterion-based DSP Vanilla BO.<i>Main results.</i>DSP Vanilla BO plans demonstrated superior dose conformity (CI95%PTV45&CI80%PTV45) and organs at risk (OAR) sparing (V40GyBowel,V30GyBowel,V40GyBladder,V40GyRectum,D0.01%femoral heads,Dmeanfemoral heads, andDmeankidneys) compared to manual planning with significant improvements (<i>p</i>< 0.05), while maintaining adequate clinical target coverage for CTV<sub>N</sub>, PTV<sub>55</sub>, ITV<sub>45</sub>, and PTV<sub>45</sub>. Compared to SAASBO, DSP Vanilla BO achieved comparable dosimetric quality but with less computation time (∼94 vs 360 min). The addition of stopping criteria further reduced the optimization time to ∼44 min while maintaining a plan quality comparable to manual planning.<i>Significance.</i>The study demonstrated that DSP Vanilla BO automated plans achieved comparable target coverage, with an improvement in OAR sparing, compared to manual plans. This highlights its effectiveness as an efficient, data-independent method for automating IMRT planning, which can be easily integrated into a TPS and benefit clinics with limited resources.

Physics in Medicine and BiologyVol. 70(23)
Homi Bhabha National Institute (IN), Banaras Hindu University (IN)
Openalex Percentile: Top 54%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.