Validity and Reliability of a Low-Cost and Portable Option for Measuring Peak and Explosive Isometric Quadriceps and Hamstrings Strength

Abstract Purpose Dynamometers are commonly used to assess muscle force properties, with isokinetic dynamometers (IKD) considered the gold standard. However, their high cost and limited portability have led to the development of alternative devices. In this study, we investigated validity and reliability of a tension dynamometer (Tindeq) compared to an IKD and how different methods of determining peak torque and rate of torque development (RTD) influence measurement properties. Methods Twenty-eight healthy university students (23.14 ± 4.06 years) completed isometric knee extension (KE) and flexion (KF) testing. Validity and reliability of peak torque and RTD were assessed using ICC , minimal detectable change (MDC), correlation (R), and Bland Altman plots across three methods: average of three trials, highest of three trials, and a single trial. Results Peak torque demonstrated good validity ( ICC = 0.80–0.88) across all methods, only KF demonstrating minimal bias (< 2% of mean). Respectively, excellent and good reliability for peak torque was observed for KE ( ICC = 0.94–0.95, MDC = 24.90%–26.81%) and KF ( ICC = 0.80–0.82, MDC = 35.08%–35.79%). Most Tindeq RTD measures demonstrated poor-moderate validity and systematically underestimated RTD (bias: 9.6%–67.5% of mean), only KF average and highest methods RTD20%–80% performed good ( ICC = 0.80–0.84). RTD20%–80% methods performed moderately ( ICC = 0.70–0.75, MDC = 69.23%–91.60%), except for the first trial method which performed poorly ( ICC = 0.25–0.48, MDC = 112.44%–179.17%). Peak RTD methods demonstrated moderate-good reliability but with large MDC ( ICC = 0.73–0.88, MDC = 49.06%–75.63%). Conclusion Tindeq demonstrates strong validity and reliability for peak torque assessment, supporting it as a portable, low-cost alternative for knee strength testing. Tindeq RTD measurement properties were less consistent, likely stemming from differences in sampling rate and processing differences.

Authors

Institutions

Publication Details

Journal
Journal of Science in Sport and Exercise
Published
2025-11-25
DOI
https://doi.org/10.1007/s42978-025-00353-9
Primary Topic
Sports injuries and prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity and Reliability of a Low-Cost and Portable Option for Measuring Peak and Explosive Isometric Quadriceps and Hamstrings Strength

Darin A. Padua, Jeffrey A. Turner, Samuel Noel, Matthew T. Hartshorne et al.
Journal of Science in Sport and Exercise
Sports injuries and prevention
article

Validity and Reliability of a Low-Cost and Portable Option for Measuring Peak and Explosive Isometric Quadriceps and Hamstrings Strength

Darin A. Padua, Jeffrey A. Turner, Samuel Noel, Matthew T. Hartshorne, Nicholas A. Buonchristiani
article en

Abstract

Abstract Purpose Dynamometers are commonly used to assess muscle force properties, with isokinetic dynamometers (IKD) considered the gold standard. However, their high cost and limited portability have led to the development of alternative devices. In this study, we investigated validity and reliability of a tension dynamometer (Tindeq) compared to an IKD and how different methods of determining peak torque and rate of torque development (RTD) influence measurement properties. Methods Twenty-eight healthy university students (23.14 ± 4.06 years) completed isometric knee extension (KE) and flexion (KF) testing. Validity and reliability of peak torque and RTD were assessed using ICC , minimal detectable change (MDC), correlation (R), and Bland Altman plots across three methods: average of three trials, highest of three trials, and a single trial. Results Peak torque demonstrated good validity ( ICC = 0.80–0.88) across all methods, only KF demonstrating minimal bias (< 2% of mean). Respectively, excellent and good reliability for peak torque was observed for KE ( ICC = 0.94–0.95, MDC = 24.90%–26.81%) and KF ( ICC = 0.80–0.82, MDC = 35.08%–35.79%). Most Tindeq RTD measures demonstrated poor-moderate validity and systematically underestimated RTD (bias: 9.6%–67.5% of mean), only KF average and highest methods RTD20%–80% performed good ( ICC = 0.80–0.84). RTD20%–80% methods performed moderately ( ICC = 0.70–0.75, MDC = 69.23%–91.60%), except for the first trial method which performed poorly ( ICC = 0.25–0.48, MDC = 112.44%–179.17%). Peak RTD methods demonstrated moderate-good reliability but with large MDC ( ICC = 0.73–0.88, MDC = 49.06%–75.63%). Conclusion Tindeq demonstrates strong validity and reliability for peak torque assessment, supporting it as a portable, low-cost alternative for knee strength testing. Tindeq RTD measurement properties were less consistent, likely stemming from differences in sampling rate and processing differences.

Journal of Science in Sport and Exercise
University of North Carolina at Chapel Hill (US), Wright-Patterson Air Force Base (US)
U.S. Department of Defense
Openalex Percentile: Top 54%
Sports injuries and prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.