Time-resolved ion mass spectrometry analysis reveal high Bi2+ and Bi3+ ion fluxes during high-power impulse magnetron sputtering of Bi target

Time-resolved ion mass spectrometry was used to investigate the ion fluxes present during high-power impulse magnetron sputtering of a Bi target in an argon atmosphere. The study focuses on the temporal evolution of singly, doubly, and triply charged Bi ions (Bi+, Bi2+, and Bi3+) under two different discharge conditions with varying peak target current densities (JT) and pulse frequencies (f). The results show that Bi2+ and Bi3+ ions dominate the ion population in the postpulse plasma, with Bi2+ exhibiting the highest flux across both discharge conditions. Interestingly, the lower peak target current density JT = 0.07 A/cm2 (f = 2000 Hz) results in higher total ion fluxes and longer ion persistence compared to those detected with JT of 0.18 A/cm2 (f = 700 Hz). Severe Ar gas rarefaction, enhanced by the high sputter yield and large mass of Bi, strongly influences the ion energy distribution functions. Both Bi2+ and Bi3+ exhibit a dominant low-energy peak (0–10 eV) from ions emitted in preceding pulses, together with broad Sigmund–Thompson-like tails extending up to ∼25–30 eV due to ions generated during the ongoing discharge. At JT = 0.07 A/cm2 (f = 2000Hz), the short off-time (470 μs) is insufficient for full ion thermalization, resulting in residual high-energy ions persisting into the early afterglow. In contrast, at 0.18 A/cm2 (f = 700 Hz), the longer off-time (∼1.4 ms) enables complete thermalization. As a result, the mean ion charge state remains above 2.0 in both cases but is slightly higher at lower JT (2.17–2.28 vs 2.07–2.15). These findings provide practical guidelines for substrate biasing: bias should be applied after ∼90 μs to minimize Ar implantation and optimized at reduced amplitudes (2–3 times lower than for Ta or W) to take advantage of the high Bi charge states without inducing excessive ion damage.

Authors

Institutions

Publication Details

Journal
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Published
2025-11-25
DOI
https://doi.org/10.1116/6.0004943
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-resolved ion mass spectrometry analysis reveal high Bi2+ and Bi3+ ion fluxes during high-power impulse magnetron sputtering of Bi target

Bartosz Wicher, Grzegorz Greczyński, Sanjay Kumar
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Metal and Thin Film Mechanics
article

Time-resolved ion mass spectrometry analysis reveal high Bi2+ and Bi3+ ion fluxes during high-power impulse magnetron sputtering of Bi target

Bartosz Wicher, Grzegorz Greczyński, Sanjay Kumar
article en

Abstract

Time-resolved ion mass spectrometry was used to investigate the ion fluxes present during high-power impulse magnetron sputtering of a Bi target in an argon atmosphere. The study focuses on the temporal evolution of singly, doubly, and triply charged Bi ions (Bi+, Bi2+, and Bi3+) under two different discharge conditions with varying peak target current densities (JT) and pulse frequencies (f). The results show that Bi2+ and Bi3+ ions dominate the ion population in the postpulse plasma, with Bi2+ exhibiting the highest flux across both discharge conditions. Interestingly, the lower peak target current density JT = 0.07 A/cm2 (f = 2000 Hz) results in higher total ion fluxes and longer ion persistence compared to those detected with JT of 0.18 A/cm2 (f = 700 Hz). Severe Ar gas rarefaction, enhanced by the high sputter yield and large mass of Bi, strongly influences the ion energy distribution functions. Both Bi2+ and Bi3+ exhibit a dominant low-energy peak (0–10 eV) from ions emitted in preceding pulses, together with broad Sigmund–Thompson-like tails extending up to ∼25–30 eV due to ions generated during the ongoing discharge. At JT = 0.07 A/cm2 (f = 2000Hz), the short off-time (470 μs) is insufficient for full ion thermalization, resulting in residual high-energy ions persisting into the early afterglow. In contrast, at 0.18 A/cm2 (f = 700 Hz), the longer off-time (∼1.4 ms) enables complete thermalization. As a result, the mean ion charge state remains above 2.0 in both cases but is slightly higher at lower JT (2.17–2.28 vs 2.07–2.15). These findings provide practical guidelines for substrate biasing: bias should be applied after ∼90 μs to minimize Ar implantation and optimized at reduced amplitudes (2–3 times lower than for Ta or W) to take advantage of the high Bi charge states without inducing excessive ion damage.

Journal of Vacuum Science & Technology A Vacuum Surfaces and FilmsVol. 43(6)
Warsaw University of Technology (PL), Thinfilm (Sweden) (SE)
VINNOVA, Linköpings Universitet, Politechnika Warszawska, Energimyndigheten
Openalex Percentile: Top 59%
Metal and Thin Film Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.