Clumped isotope measurements on nanomoles of CO <sub>2</sub> using a hollow core fiber-based spectrometer

The abundance of carbon dioxide (CO<sub>2</sub>) clumped isotopologues is an important tracer of environmental conditions in both atmospheric and paleoclimatic contexts. However, the conventional method for accurate CO<sub>2</sub> clumped isotope measurements, based on magnetic sector isotope ratio mass spectrometers (IRMSs), is time-consuming (hours per replicate) and requires large sample sizes (up to 100 µmoles CO<sub>2</sub>). The recent development of isotope ratio laser spectrometers (IRLSs) determines CO<sub>2</sub> clumped isotope composition based on the infrared absorption spectra of corresponding CO<sub>2</sub> isotopologues and has significantly decreased the duration of clumped isotope measurements (minutes per replicate). However, existing IRLS instruments still require similar sample sizes to current IRMSs. Here, we present, to the best of our knowledge, a new IRLS prototype that demonstrates the feasibility of performing clumped isotope measurements using only nanomoles of CO<sub>2</sub>. The instrument leverages hollow core fiber (HCF) technology and achieves a reduction in sample size of about four orders of magnitude compared to existing IRLSs. We successfully detect and quantify the clumped isotopologues <sup>16</sup>O<sup>13</sup>C<sup>18</sup>O and <sup>18</sup>O<sup>12</sup>C<sup>18</sup>O absorption using ∼17 nanomoles of CO<sub>2</sub> and measure their abundances to precisions of 0.7‰ and 1.0‰, respectively in 1-1.5 minutes. Combining them with three other measured isotopologue lines we are able to calculate the clumped isotope ratios Δ<sub>638</sub> and Δ<sub>828</sub>, achieving precisions of 0.7‰ and 1.8‰ in 15-30 seconds. Our results demonstrate the potential of HCF technology for clumped isotope analyses of nanomoles of CO<sub>2</sub> with future technical improvements particularly in mid-infrared fiber technology.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-11-25
DOI
https://doi.org/10.1364/oe.582189
Primary Topic
Paleontology and Stratigraphy of Fossils
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clumped isotope measurements on nanomoles of CO 2 using a hollow core fiber-based spectrometer

Anna P. M. Michel, Jason Kapit, Weifu Guo, Scott T. Wieman
Optics Express
Paleontology and Stratigraphy of Fossils
article

Clumped isotope measurements on nanomoles of CO 2 using a hollow core fiber-based spectrometer

Anna P. M. Michel, Jason Kapit, Weifu Guo, Scott T. Wieman
article en

Abstract

The abundance of carbon dioxide (CO<sub>2</sub>) clumped isotopologues is an important tracer of environmental conditions in both atmospheric and paleoclimatic contexts. However, the conventional method for accurate CO<sub>2</sub> clumped isotope measurements, based on magnetic sector isotope ratio mass spectrometers (IRMSs), is time-consuming (hours per replicate) and requires large sample sizes (up to 100 µmoles CO<sub>2</sub>). The recent development of isotope ratio laser spectrometers (IRLSs) determines CO<sub>2</sub> clumped isotope composition based on the infrared absorption spectra of corresponding CO<sub>2</sub> isotopologues and has significantly decreased the duration of clumped isotope measurements (minutes per replicate). However, existing IRLS instruments still require similar sample sizes to current IRMSs. Here, we present, to the best of our knowledge, a new IRLS prototype that demonstrates the feasibility of performing clumped isotope measurements using only nanomoles of CO<sub>2</sub>. The instrument leverages hollow core fiber (HCF) technology and achieves a reduction in sample size of about four orders of magnitude compared to existing IRLSs. We successfully detect and quantify the clumped isotopologues <sup>16</sup>O<sup>13</sup>C<sup>18</sup>O and <sup>18</sup>O<sup>12</sup>C<sup>18</sup>O absorption using ∼17 nanomoles of CO<sub>2</sub> and measure their abundances to precisions of 0.7‰ and 1.0‰, respectively in 1-1.5 minutes. Combining them with three other measured isotopologue lines we are able to calculate the clumped isotope ratios Δ<sub>638</sub> and Δ<sub>828</sub>, achieving precisions of 0.7‰ and 1.8‰ in 15-30 seconds. Our results demonstrate the potential of HCF technology for clumped isotope analyses of nanomoles of CO<sub>2</sub> with future technical improvements particularly in mid-infrared fiber technology.

Optics ExpressVol. 33(25)
Woods Hole Oceanographic Institution (US)
Openalex Percentile: Top 84%
Paleontology and Stratigraphy of Fossils
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.