Innovative ultrasound-assisted and vacuum manifold-assisted pipette tip solid-phase extraction using MSU-2-C18 sorbent for the extraction and purification of glycoalkaloids in potato-based snacks prior to UHPLC-MS/MS analysis

A miniaturized and environmentally conscious analytical workflow was developed and validated for the extraction, purification, and quantification of major glycoalkaloids (α-solanine, α-chaconine), the degradation product γ-chaconine, and the aglycone solanidine in potato-based snack products. The method combines ultrasound-assisted extraction (UAE) with pipette-tip solid-phase extraction (PT-SPE), followed by UHPLC-MS/MS analysis. UAE conditions were optimized using a Box-Behnken statistical design, which evaluated the extraction time, ultrasound amplitude, and solid:liquid (SL) ratio. Optimal conditions were determined to be 5 min, 100% amplitude, and a 1:9 w/v of SL ratio, with methanol as the most effective extraction solvent. MSU-2-C18 mesostructured silica sorbent, packed into pipette tips (5 mg) connected to a SPE vacuum manifold (VMA-PT-SPE), was employed under the optimized conditions to simultaneously purify up to 12 extracts. The method's greenness was evaluated using the AGREEprep metric, yielding a score of 0.65, indicating good environmental performance. Limits of detection (LOD) and quantification (LOQ), ranging from 0.55-4.40 µg/kg and 1.82-14.67 µg/kg, respectively, were achieved for the target analytes. Application to four commercial potato-based snacks revealed major (α-solanine and α-chaconine) and minor glycoalkaloids (γ-chaconine and solanidine) levels, ranging from 2.0 to 16.0 mg/kg fresh weight, highlighting substantial variability among products and providing a more comprehensive characterization of the glycoalkaloid profile. Compared to conventional SPE formats, this UAE-VMA-PT-SPE strategy offers superior reproducibility while reducing sample and solvent consumption. The method represents a powerful tool for routine monitoring of glycoalkaloids in potato snacks, supporting food safety assessments and addressing analytical priorities established by the European Food Safety Authority.

Authors

Institutions

Publication Details

Journal
Advances in Sample Preparation
Published
2025-11-25
DOI
https://doi.org/10.1016/j.sampre.2025.100228
Primary Topic
Potato Plant Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative ultrasound-assisted and vacuum manifold-assisted pipette tip solid-phase extraction using MSU-2-C18 sorbent for the extraction and purification of glycoalkaloids in potato-based snacks prior to UHPLC-MS/MS analysis

Damián Pérez‐Quintanilla, Isabel Sierra, Sonia Morante‐Zarcero, Isabel Martínez-García
Advances in Sample Preparation
Potato Plant Research
article

Innovative ultrasound-assisted and vacuum manifold-assisted pipette tip solid-phase extraction using MSU-2-C18 sorbent for the extraction and purification of glycoalkaloids in potato-based snacks prior to UHPLC-MS/MS analysis

Damián Pérez‐Quintanilla, Isabel Sierra, Sonia Morante‐Zarcero, Isabel Martínez-García
article en

Abstract

A miniaturized and environmentally conscious analytical workflow was developed and validated for the extraction, purification, and quantification of major glycoalkaloids (α-solanine, α-chaconine), the degradation product γ-chaconine, and the aglycone solanidine in potato-based snack products. The method combines ultrasound-assisted extraction (UAE) with pipette-tip solid-phase extraction (PT-SPE), followed by UHPLC-MS/MS analysis. UAE conditions were optimized using a Box-Behnken statistical design, which evaluated the extraction time, ultrasound amplitude, and solid:liquid (SL) ratio. Optimal conditions were determined to be 5 min, 100% amplitude, and a 1:9 w/v of SL ratio, with methanol as the most effective extraction solvent. MSU-2-C18 mesostructured silica sorbent, packed into pipette tips (5 mg) connected to a SPE vacuum manifold (VMA-PT-SPE), was employed under the optimized conditions to simultaneously purify up to 12 extracts. The method's greenness was evaluated using the AGREEprep metric, yielding a score of 0.65, indicating good environmental performance. Limits of detection (LOD) and quantification (LOQ), ranging from 0.55-4.40 µg/kg and 1.82-14.67 µg/kg, respectively, were achieved for the target analytes. Application to four commercial potato-based snacks revealed major (α-solanine and α-chaconine) and minor glycoalkaloids (γ-chaconine and solanidine) levels, ranging from 2.0 to 16.0 mg/kg fresh weight, highlighting substantial variability among products and providing a more comprehensive characterization of the glycoalkaloid profile. Compared to conventional SPE formats, this UAE-VMA-PT-SPE strategy offers superior reproducibility while reducing sample and solvent consumption. The method represents a powerful tool for routine monitoring of glycoalkaloids in potato snacks, supporting food safety assessments and addressing analytical priorities established by the European Food Safety Authority.

Advances in Sample PreparationVol. 17
Universidad Rey Juan Carlos (ES)
Openalex Percentile: Top 58%
Potato Plant Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.