Comparison of the Performance of Fluorescent, Phosphorescent, and TADF Luminophores for Explosives Sensing

ABSTRACT This study investigates how the emission mechanism (fluorescence, phosphorescence, or thermally activated delayed fluorescence, TADF) of a luminescence‐quenching chemical sensor influences the sensitivity of explosives detection. Steady‐state and time‐resolved photoluminescence measurements were used to evaluate the quenching kinetics of representative emitters in the presence of 2,4‐dinitrotoluene ( DNT ), a model nitroaromatic explosive. Linear Stern‐Volmer behavior was observed for the fluorescent and phosphorescent emitters, whereas the TADF compound exhibited a pronounced downward deviation in steady‐state measurements, arising from the simultaneous but distinct quenching of singlet and triplet exciton populations. To describe this behavior, we derived a modified Stern–Volmer formalism comprising separate relationships for the prompt and delayed fluorescence. The quenching dynamics of the TADF system were found to be strongly dependent on the intrinsic parameters , k Stot and k Ttot , with the singlet and triplet populations being quenched with different efficiencies. These insights highlight the potential of TADF luminophores to act as sensitive photoinduced electron transfer‐based explosives sensors.

Authors

Institutions

Publication Details

Journal
Advanced Sensor Research
Published
2025-11-23
DOI
https://doi.org/10.1002/adsr.202500137
Primary Topic
Luminescence and Fluorescent Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Performance of Fluorescent, Phosphorescent, and TADF Luminophores for Explosives Sensing

Graham A. Turnbull, Eli Zysman‐Colman, Michele Duarte Tonet
Advanced Sensor Research
Luminescence and Fluorescent Materials
article

Comparison of the Performance of Fluorescent, Phosphorescent, and TADF Luminophores for Explosives Sensing

Graham A. Turnbull, Eli Zysman‐Colman, Michele Duarte Tonet
article en

Abstract

ABSTRACT This study investigates how the emission mechanism (fluorescence, phosphorescence, or thermally activated delayed fluorescence, TADF) of a luminescence‐quenching chemical sensor influences the sensitivity of explosives detection. Steady‐state and time‐resolved photoluminescence measurements were used to evaluate the quenching kinetics of representative emitters in the presence of 2,4‐dinitrotoluene ( DNT ), a model nitroaromatic explosive. Linear Stern‐Volmer behavior was observed for the fluorescent and phosphorescent emitters, whereas the TADF compound exhibited a pronounced downward deviation in steady‐state measurements, arising from the simultaneous but distinct quenching of singlet and triplet exciton populations. To describe this behavior, we derived a modified Stern–Volmer formalism comprising separate relationships for the prompt and delayed fluorescence. The quenching dynamics of the TADF system were found to be strongly dependent on the intrinsic parameters , k Stot and k Ttot , with the singlet and triplet populations being quenched with different efficiencies. These insights highlight the potential of TADF luminophores to act as sensitive photoinduced electron transfer‐based explosives sensors.

Advanced Sensor ResearchVol. 5(1)
University of St Andrews (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 70%
Luminescence and Fluorescent Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.