Use of Expected Utility to Evaluate Artificial Intelligence–Enabled Rule-out Devices for Mammography Screening

BackgroundAn artificial intelligence (AI)-enabled rule-out device may autonomously remove patient images unlikely to have cancer from radiologist review. Many published studies evaluate this type of device by retrospectively applying the AI to large datasets and use sensitivity and specificity as the performance metrics. However, these metrics have fundamental shortcomings because sensitivity will always be negatively affected in retrospective studies of rule-out applications of AI.MethodWe reviewed 2 performance metrics to compare the screening performance between the radiologist-with-rule-out-device and radiologist-without-device workflows: positive/negative predictive values (PPV/NPV) and expected utility (EU). We applied both methods to a recent study that reported improved performance in the radiologist-with-device workflow using a retrospective US dataset. We then applied the EU method to a European study based on the reported recall and cancer detection rates at different AI thresholds to compare the potential utility among different thresholds.ResultsFor the US study, neither PPV/NPV nor EU can demonstrate significant improvement for any of the algorithm thresholds reported. For the study using European data, we found that EU is lower as AI rules out more patients including false-negative cases and reduces the overall screening performance.ConclusionsDue to the nature of the retrospective simulated study design, sensitivity and specificity can be ambiguous in evaluating a rule-out device. We showed that using PPV/NPV or EU can resolve the ambiguity. The EU method can be applied with only recall rates and cancer detection rates, which is convenient as ground truth is often unavailable for nonrecalled patients in screening mammography.HighlightsSensitivity and specificity can be ambiguous metrics for evaluating a rule-out device in a retrospective setting. PPV and NPV can resolve the ambiguity but require the ground truth for all patients. Based on utility theory, expected utility (EU) is a potential metric that helps demonstrate improvement in screening performance due to a rule-out device using large retrospective datasets.We applied EU to a recent study that used a large retrospective mammography screening dataset from the United States. That study reported an improvement in specificity and decrease in sensitivity when using their AI as a rule-out device retrospectively. In terms of EU, we cannot conclude a significant improvement when the AI is used as a rule-out device.We applied the method to a European study that reported only recall rates and cancer detection rates. Since there is no established EU baseline value in European mammography screening workflow, we estimated the EU baseline using data from previous literature. We cannot conclude a significant improvement when the AI is used as a rule-out device for the European study.In this work, we investigated the use of EU to evaluate rule-out devices using large retrospective datasets. This metric, used with retrospective clinical data, could be used as supporting evidence for rule-out devices.

Authors

Institutions

Publication Details

Journal
Medical Decision Making
Published
2025-11-24
DOI
https://doi.org/10.1177/0272989x251388665
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Expected Utility to Evaluate Artificial Intelligence–Enabled Rule-out Devices for Mammography Screening

Weijie Chen, Craig K. Abbey, F. W. Samuelson, Yee Lam Elim Thompson et al.
Medical Decision Making
AI in cancer detection
article

Use of Expected Utility to Evaluate Artificial Intelligence–Enabled Rule-out Devices for Mammography Screening

Weijie Chen, Craig K. Abbey, F. W. Samuelson, Yee Lam Elim Thompson, Kwok Lung Fan
article en

Abstract

BackgroundAn artificial intelligence (AI)-enabled rule-out device may autonomously remove patient images unlikely to have cancer from radiologist review. Many published studies evaluate this type of device by retrospectively applying the AI to large datasets and use sensitivity and specificity as the performance metrics. However, these metrics have fundamental shortcomings because sensitivity will always be negatively affected in retrospective studies of rule-out applications of AI.MethodWe reviewed 2 performance metrics to compare the screening performance between the radiologist-with-rule-out-device and radiologist-without-device workflows: positive/negative predictive values (PPV/NPV) and expected utility (EU). We applied both methods to a recent study that reported improved performance in the radiologist-with-device workflow using a retrospective US dataset. We then applied the EU method to a European study based on the reported recall and cancer detection rates at different AI thresholds to compare the potential utility among different thresholds.ResultsFor the US study, neither PPV/NPV nor EU can demonstrate significant improvement for any of the algorithm thresholds reported. For the study using European data, we found that EU is lower as AI rules out more patients including false-negative cases and reduces the overall screening performance.ConclusionsDue to the nature of the retrospective simulated study design, sensitivity and specificity can be ambiguous in evaluating a rule-out device. We showed that using PPV/NPV or EU can resolve the ambiguity. The EU method can be applied with only recall rates and cancer detection rates, which is convenient as ground truth is often unavailable for nonrecalled patients in screening mammography.HighlightsSensitivity and specificity can be ambiguous metrics for evaluating a rule-out device in a retrospective setting. PPV and NPV can resolve the ambiguity but require the ground truth for all patients. Based on utility theory, expected utility (EU) is a potential metric that helps demonstrate improvement in screening performance due to a rule-out device using large retrospective datasets.We applied EU to a recent study that used a large retrospective mammography screening dataset from the United States. That study reported an improvement in specificity and decrease in sensitivity when using their AI as a rule-out device retrospectively. In terms of EU, we cannot conclude a significant improvement when the AI is used as a rule-out device.We applied the method to a European study that reported only recall rates and cancer detection rates. Since there is no established EU baseline value in European mammography screening workflow, we estimated the EU baseline using data from previous literature. We cannot conclude a significant improvement when the AI is used as a rule-out device for the European study.In this work, we investigated the use of EU to evaluate rule-out devices using large retrospective datasets. This metric, used with retrospective clinical data, could be used as supporting evidence for rule-out devices.

Medical Decision MakingVol. 46(3)
United States Food and Drug Administration (US), University of California, Santa Barbara (US)
Openalex Percentile: Top 81%
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.