Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study

Objectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 ± 4.97 years; body mass index: 25.79 ± 3.02 kg/m2) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland–Altman analysis and Pearson’s correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86–0.91) and moderate-to-good inter-platform reliability (ICC = 0.75–0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75–0.87) and higher variability (CV = 47–57%). Bland–Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R2 = 0.55–0.77; β = 0.74–0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-11-22
DOI
https://doi.org/10.3390/app152312409
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study

Alejandro Pérez‐Castilla, Héctor Fuentes-Barría, Ángel Roco-Videla, Diana Rojas-Gómez et al.
Applied Sciences
Sports Performance and Training
article

Validation of the G-Force Platform for Isometric Tests in Physically Active Young Adults: A Pilot Study

Alejandro Pérez‐Castilla, Héctor Fuentes-Barría, Ángel Roco-Videla, Diana Rojas-Gómez, Raul Alberto Aguilera-Eguía, Víctor Garrido-Osorio, Luis Romero-Vera, Alberto Ñancupil-Andrade, Jorge Leschot-Gatica, Sebastián Sanhueza-González, Mauricio Quidel
article en

Abstract

Objectives: To evaluate the validity, accuracy, and reliability of the G-Force force platform during isometric tests, through comparison with a gold-standard force platform in physically active young adults. Methods: Nine physically active participants (23.67 ± 4.97 years; body mass index: 25.79 ± 3.02 kg/m2) performed isometric posterior lower limb muscle tests per leg, following a standardized warm-up and familiarization protocol. The G-Force platform and compared against a gold-standard device, the Valkyria Trainer Balance (VTB) force platform. The measured variables included Peak Force and peak rate of force development (RFD) at 50, 100 and 150 ms (RFD50, RFD100 and RFD150). Intra- and inter-platform reliability were assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV%), Bland–Altman analysis and Pearson’s correlation coefficients between both platforms. Results: Peak Force showed excellent intra-platform repeatability (ICC = 0.86–0.91) and moderate-to-good inter-platform reliability (ICC = 0.75–0.77), with the G-Force platform generally reporting slightly lower absolute values than VTB. RFD measures demonstrated moderate reproducibility (ICC = 0.75–0.87) and higher variability (CV = 47–57%). Bland–Altman analyses revealed minimal bias for Peak Force, while regression analyses indicated strong, significant associations between G-Force and VTB measurements (R2 = 0.55–0.77; β = 0.74–0.88; p < 0.05). Conclusions: The G-Force force platform is a valid, reliable, and low-cost tool for assessing isometric strength in physically active young adults.

Applied SciencesVol. 15(23)
University of Concepción (CL), Universidad Autónoma de Chile (CL), Universidad Católica de la Santísima Concepción (CL), Universidad Andrés Bello (CL), Universidad Santo Tomás (CL), Universidad de Los Lagos (CL), University of Almería (ES), Arturo Prat University (CL)
Openalex Percentile: Top 54%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.