Performance and Economic Analysis of a High-Efficiency Wide-Working Load Distillation System with Combined Ejector

A distillation system with an ejector for secondary steam utilization can effectively improve energy efficiency. However, the poor performance of the ejector under varying operating conditions makes it difficult for the distillation system to adapt to wide-range operational requirements. To address this challenge, a distillation system using a combined ejector with staged and continuous adjustment is proposed, and its performance and economic feasibility under wide load conditions is analyzed. The results show that when a combined ejector is used—composed of four fixed-structure ejectors with capacities of 6.25%, 12.5%, 25%, and 50%, along with a nozzle needle-adjustable ejector with a capacity range of 0–6.25%—the distillation system can combine the advantages of both staged and continuous adjustment. This system can utilize secondary steam across a load range of 2.53–100%, whereas a distillation system with a single continuously adjustable ejector can only utilize secondary steam within a load range of 40.5–100%. As the load varies from 0 to 100%, the proposed system achieves an average entrainment ratio of 0.525, with an efficiency not less than 50% of the design value over 95.23% of the range. In contrast, the conventional single continuously adjustable ejector has an average entrainment ratio of 0.177, and the distillation system efficiency remains above 50% of the design value for only 25.32% of the range. In a solar-assisted distillation system, the combined ejector improves the coefficient of performance (COP) by over 30%, with a payback period of less than one year. The findings highlight the system’s superior adaptability, efficiency, and economic viability for applications with unstable energy supply.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-11-23
DOI
https://doi.org/10.3390/pr13123783
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and Economic Analysis of a High-Efficiency Wide-Working Load Distillation System with Combined Ejector

Wenfeng Liang, Bingxu Chen, Hongjie Chen, Huamao Huang et al.
Processes
Refrigeration and Air Conditioning Technologies
article

Performance and Economic Analysis of a High-Efficiency Wide-Working Load Distillation System with Combined Ejector

Wenfeng Liang, Bingxu Chen, Hongjie Chen, Huamao Huang, Lin Xia, Zhizhou Xu
article en

Abstract

A distillation system with an ejector for secondary steam utilization can effectively improve energy efficiency. However, the poor performance of the ejector under varying operating conditions makes it difficult for the distillation system to adapt to wide-range operational requirements. To address this challenge, a distillation system using a combined ejector with staged and continuous adjustment is proposed, and its performance and economic feasibility under wide load conditions is analyzed. The results show that when a combined ejector is used—composed of four fixed-structure ejectors with capacities of 6.25%, 12.5%, 25%, and 50%, along with a nozzle needle-adjustable ejector with a capacity range of 0–6.25%—the distillation system can combine the advantages of both staged and continuous adjustment. This system can utilize secondary steam across a load range of 2.53–100%, whereas a distillation system with a single continuously adjustable ejector can only utilize secondary steam within a load range of 40.5–100%. As the load varies from 0 to 100%, the proposed system achieves an average entrainment ratio of 0.525, with an efficiency not less than 50% of the design value over 95.23% of the range. In contrast, the conventional single continuously adjustable ejector has an average entrainment ratio of 0.177, and the distillation system efficiency remains above 50% of the design value for only 25.32% of the range. In a solar-assisted distillation system, the combined ejector improves the coefficient of performance (COP) by over 30%, with a payback period of less than one year. The findings highlight the system’s superior adaptability, efficiency, and economic viability for applications with unstable energy supply.

ProcessesVol. 13(12)
Queensland University of Technology (AU), The University of Queensland (AU), Guilin University of Aerospace Technology (CN)
Natural Science Foundation of Guangxi Province
Openalex Percentile: Top 62%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.