Seismic Performance Analysis of Hybrid Damped Structures in High-Intensity Seismic Regions

This study was conducted based on hybrid damping control theory, and an equivalent damping ratio calculation method was proposed. Additionally, a response calculation method for the elastoplastic stage of the hybrid control system was developed. Furthermore, a cooperative working mechanism between viscous dampers and metal composite dampers was introduced. A time–history analysis was employed to verify the system’s effectiveness in optimizing the multi-dimensional seismic performance of frame structures. Using actual engineering as the research background, an elastoplastic analysis of the hybrid control system was conducted. The analysis results show that the first three natural periods of vibration were shortened by 6.1% (in the X direction), 5.9% (in the Y direction), and 21.0% (torsion), effectively enhancing the overall stiffness of the structure. Under seismic action, the inter-story displacement decreased by 37.1% to 0.166 m in the X direction and by 48.3% to 0.080 m in the Y direction; the base shear forces were reduced by 58.8% (in the X direction) and 41.7% (in the Y direction). Regarding damage control, the number of plastic hinges was significantly reduced, and they appeared only on the most unfavorable floors; the axial compressive stress peaks in the frame columns were strictly controlled below 0.65 fc, and the inter-story displacement angles (<1/50) met the standards of GB50011-2010 for key protection structures. The hybrid system demonstrated multi-dimensional synergistic effects, whereby the viscous dampers primarily controlled the acceleration responses in the X direction, while the metal composite dampers dominated energy dissipation in Y displacement. The difference in seismic reduction efficiency between the two main axes was less than 11%, and a 21% improvement in the torsional period was achieved simultaneously.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-11-23
DOI
https://doi.org/10.3390/buildings15234229
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Performance Analysis of Hybrid Damped Structures in High-Intensity Seismic Regions

Alipujiang Jierula, Yejun Wu, Jinghui Wang, Qing Liu et al.
Buildings
Vibration Control and Rheological Fluids
article

Seismic Performance Analysis of Hybrid Damped Structures in High-Intensity Seismic Regions

Alipujiang Jierula, Yejun Wu, Jinghui Wang, Qing Liu, Yongfei Jin, Shan Liu
article en

Abstract

This study was conducted based on hybrid damping control theory, and an equivalent damping ratio calculation method was proposed. Additionally, a response calculation method for the elastoplastic stage of the hybrid control system was developed. Furthermore, a cooperative working mechanism between viscous dampers and metal composite dampers was introduced. A time–history analysis was employed to verify the system’s effectiveness in optimizing the multi-dimensional seismic performance of frame structures. Using actual engineering as the research background, an elastoplastic analysis of the hybrid control system was conducted. The analysis results show that the first three natural periods of vibration were shortened by 6.1% (in the X direction), 5.9% (in the Y direction), and 21.0% (torsion), effectively enhancing the overall stiffness of the structure. Under seismic action, the inter-story displacement decreased by 37.1% to 0.166 m in the X direction and by 48.3% to 0.080 m in the Y direction; the base shear forces were reduced by 58.8% (in the X direction) and 41.7% (in the Y direction). Regarding damage control, the number of plastic hinges was significantly reduced, and they appeared only on the most unfavorable floors; the axial compressive stress peaks in the frame columns were strictly controlled below 0.65 fc, and the inter-story displacement angles (<1/50) met the standards of GB50011-2010 for key protection structures. The hybrid system demonstrated multi-dimensional synergistic effects, whereby the viscous dampers primarily controlled the acceleration responses in the X direction, while the metal composite dampers dominated energy dissipation in Y displacement. The difference in seismic reduction efficiency between the two main axes was less than 11%, and a 21% improvement in the torsional period was achieved simultaneously.

BuildingsVol. 15(23)
CNH Industrial (Czechia) (CZ), Guangzhou Design Institute (CN), CCCC Highway Consultants (China) (CN), Xinjiang University (CN)
Openalex Percentile: Top 63%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.