Influence of Acetabular Cup Elevation Height on Contact and Failure Analysis of Metal-on-Metal Hip Prosthesis Under Mild and Severe Microseparations for Regular and Risky Gait Loads

Abstract Acetabular cup contact stress and failure analysis play a crucial role in estimating the durability of implants. Many studies have focused on the modification of acetabular cup design parameters to improve their longevity. The present study focuses on one such design consideration by varying the acetabular cup elevation height using a global model finite element conceptualization. Acetabular cup elevation height variation of 1, 2, and 3 mm with microseparations of 0.5, 1, 1.5, 2, 2.5, and 3 mm are considered to analyze contact and von Mises stress for the CoCr alloy at a 45 deg cup inclination angle. The peak gait loads of grouped gait activities, namely, A, B, C, and D, consisting of 19 gait loads, are used to estimate the aforesaid stresses. Group C and D gait load activities are very rarely performed by humans in day-to-day activities, while group A and B gait load activities are performed quite often by humans, except for a few gait activities like lifting and carrying loads. Results revealed that a cup elevation height of 3 mm was found to effectively reduce contact stress for microseparation of 2.5 and 3 mm. The 1 mm elevation height showed higher contact stress values for almost all microseparations. From von Mises plots, it is evident that the elevated acetabular cup prevents implant failure even for high microseparation values for gait loads grouped under the A and B categories. For physically demanding gait loads listed in group C and D categories, for all microseparation values, von Mises stress values of the elevated cup showed values higher than the yield stress of the CoCr alloy.

Authors

Institutions

Publication Details

Journal
Journal of Tribology
Published
2025-11-24
DOI
https://doi.org/10.1115/1.4070468
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Acetabular Cup Elevation Height on Contact and Failure Analysis of Metal-on-Metal Hip Prosthesis Under Mild and Severe Microseparations for Regular and Risky Gait Loads

M. Kalayarasan, Shankar Subramaniam, R. Naveenkumar, Chander Prakash et al.
Journal of Tribology
Orthopaedic implants and arthroplasty
article

Influence of Acetabular Cup Elevation Height on Contact and Failure Analysis of Metal-on-Metal Hip Prosthesis Under Mild and Severe Microseparations for Regular and Risky Gait Loads

M. Kalayarasan, Shankar Subramaniam, R. Naveenkumar, Chander Prakash, Ghulam Abbas, Animesh Kumar Basak, Alokesh Pramanik, R. Nithyaprakash, Jashwanth Krishna, M Manikandan, S. K. Thangarasu, A. P. Sugunesh
article en

Abstract

Abstract Acetabular cup contact stress and failure analysis play a crucial role in estimating the durability of implants. Many studies have focused on the modification of acetabular cup design parameters to improve their longevity. The present study focuses on one such design consideration by varying the acetabular cup elevation height using a global model finite element conceptualization. Acetabular cup elevation height variation of 1, 2, and 3 mm with microseparations of 0.5, 1, 1.5, 2, 2.5, and 3 mm are considered to analyze contact and von Mises stress for the CoCr alloy at a 45 deg cup inclination angle. The peak gait loads of grouped gait activities, namely, A, B, C, and D, consisting of 19 gait loads, are used to estimate the aforesaid stresses. Group C and D gait load activities are very rarely performed by humans in day-to-day activities, while group A and B gait load activities are performed quite often by humans, except for a few gait activities like lifting and carrying loads. Results revealed that a cup elevation height of 3 mm was found to effectively reduce contact stress for microseparation of 2.5 and 3 mm. The 1 mm elevation height showed higher contact stress values for almost all microseparations. From von Mises plots, it is evident that the elevated acetabular cup prevents implant failure even for high microseparation values for gait loads grouped under the A and B categories. For physically demanding gait loads listed in group C and D categories, for all microseparation values, von Mises stress values of the elevated cup showed values higher than the yield stress of the CoCr alloy.

Journal of TribologyVol. 148(5)
Lovely Professional University (IN), Madurai Medical College (IN), OSRAM (United States) (US), The University of Western Australia (AU), Thi Qar University (IQ), Curtin University (AU), Hong Kong College of Technology (CN), California Miramar University (US), PSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH (IN), Orthopaedic Research Group (IN), Linz Center of Mechatronics (Austria) (AT), The University of Adelaide (AU), Karpagam Academy of Higher Education (IN), Ithaca College (US)
Openalex Percentile: Top 45%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.