A Magnetically Controlled Capsule Robot with Biopsy Capability for Intestinal Applications

Magnetically controlled capsule robots offer unique advantages for performing intestinal biopsies. In this paper, we propose a novel Magnetically Controlled Capsule Robot for Intestinal Biopsy (MCCR-IB), capable of both navigation and biopsy within the intestine. To address the coupling issue between locomotion control and biopsy control, a magnetic field locking method is also introduced. The locomotion performance, curved-passage capability, and biopsy ability were experimentally evaluated. Under a 7 Hz rotating magnetic field, the MCCR-IB achieved forward and backward velocities of 20.22 mm/s and 18.27 mm/s, respectively, with a biopsy needle puncture force of 1.99 N. Furthermore, ex vivo experiments were conducted to preliminarily verify the feasibility of the robot's motion and biopsy functions. The experimental results demonstrate that the proposed MCCR-IB exhibits good performance and shows promising potential for future clinical applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-11-24
DOI
https://doi.org/10.3390/s25237158
Citations
1
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
1.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Magnetically Controlled Capsule Robot with Biopsy Capability for Intestinal Applications

Le Yan, Zhengdong Qi, Lingling Zheng, Haifei Zhang et al.
1 citations
Sensors
Gastrointestinal Bleeding Diagnosis and Treatment
1.81
article

A Magnetically Controlled Capsule Robot with Biopsy Capability for Intestinal Applications

Le Yan, Zhengdong Qi, Lingling Zheng, Haifei Zhang, Le Zhang, Shuxiang Guo, Zixu Wang, Jie Sun, Fen Zhao
article en
1 citations

Abstract

Magnetically controlled capsule robots offer unique advantages for performing intestinal biopsies. In this paper, we propose a novel Magnetically Controlled Capsule Robot for Intestinal Biopsy (MCCR-IB), capable of both navigation and biopsy within the intestine. To address the coupling issue between locomotion control and biopsy control, a magnetic field locking method is also introduced. The locomotion performance, curved-passage capability, and biopsy ability were experimentally evaluated. Under a 7 Hz rotating magnetic field, the MCCR-IB achieved forward and backward velocities of 20.22 mm/s and 18.27 mm/s, respectively, with a biopsy needle puncture force of 1.99 N. Furthermore, ex vivo experiments were conducted to preliminarily verify the feasibility of the robot's motion and biopsy functions. The experimental results demonstrate that the proposed MCCR-IB exhibits good performance and shows promising potential for future clinical applications.

SensorsVol. 25(23)
Southern University of Science and Technology (CN), Nanjing Xiaozhuang University (CN)
Openalex Percentile: Top 11%
Gastrointestinal Bleeding Diagnosis and Treatment
1.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Magnetically Controlled Capsule Robot with Biopsy Capability for Intestinal Applications — Le Yan, Zhengdong Qi, et al. · Sensors (2025) | TGRS Research Map | TGRS