pH calibration allows accurate glucose detection in interstitial fluid via reverse iontophoresis

Reverse iontophoresis (RI) is a promising non-invasive, wearable technology for the transdermal extraction of interstitial fluid (ISF), which contains rich biomarkers relevant to health status. Despite the advancement of wearable sensors, this technology is still restricted for accurate non-invasive biomarkers detection. The main challenge lies in the instability of ISF extraction during RI. We found that this instability is primarily caused by the skin surface pH variations because of the interaction between the RI-induced H<sup>+</sup> movement and the skin recovery ability. Here, we investigated how the skin surface pH affected RI, theoretically and experimentally; and developed a wearable device and a calibration method to enable accurate non-invasive ISF glucose detection, accordingly. The result showed that glucose prediction accuracy was markedly improved, with mean absolute relative difference (MARD) decreased from 34.44% to 14.78% across both healthy and diabetic volunteers.

Authors

Institutions

Publication Details

Journal
Nature Communications
Published
2025-11-24
DOI
https://doi.org/10.1038/s41467-025-65453-0
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

pH calibration allows accurate glucose detection in interstitial fluid via reverse iontophoresis

Mengcen Wang, Zirong Zhou, Youhao Liu, Wangwang Zhu et al.
Nature Communications
Advancements in Transdermal Drug Delivery
article

pH calibration allows accurate glucose detection in interstitial fluid via reverse iontophoresis

Mengcen Wang, Zirong Zhou, Youhao Liu, Wangwang Zhu, Zhihua Pu, Miao Deng, Hao Zheng, Xi Li, Zhenqiang Song, Chengcheng Li, Peng Guo, Wen‐Jun Li, Xingguo Zhang, Yuxiao Ma, Chenxi Jin, Mingzhen Li, Jiaqi Hou, Dachao Li
article en

Abstract

Reverse iontophoresis (RI) is a promising non-invasive, wearable technology for the transdermal extraction of interstitial fluid (ISF), which contains rich biomarkers relevant to health status. Despite the advancement of wearable sensors, this technology is still restricted for accurate non-invasive biomarkers detection. The main challenge lies in the instability of ISF extraction during RI. We found that this instability is primarily caused by the skin surface pH variations because of the interaction between the RI-induced H<sup>+</sup> movement and the skin recovery ability. Here, we investigated how the skin surface pH affected RI, theoretically and experimentally; and developed a wearable device and a calibration method to enable accurate non-invasive ISF glucose detection, accordingly. The result showed that glucose prediction accuracy was markedly improved, with mean absolute relative difference (MARD) decreased from 34.44% to 14.78% across both healthy and diabetic volunteers.

Nature CommunicationsVol. 16(1)
Tianjin University (CN), Tianjin Medical University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 70%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.