A Sequential Dual-Reagent Paper-Based Analytical Device with Structural Release Control for Point-of-Care Detection of Urinary <i>N</i> -Acetyl-β- <scp> <i>d</i> </scp> -Glucosaminidase

<i>N</i>-acetyl-β-<i>d</i>-glucosaminidase (NAG) is an important biomarker that indicates early renal tubular damage. Its activity level in urine has been widely used for early detection and monitoring of chronic kidney disease (CKD), particularly diabetic nephropathy. However, current detection methods rely on complex instrumentation, which hinders their suitability for point-of-care testing (POCT) that requires portability and user-friendliness. To address this challenge, we developed a sequential dual-reagent paper-based analytical device (SeDR-PAD) that utilizes structural partitioning and a delayed-trigger mechanism to achieve time-programmed control of the NAG enzymatic reaction and color development process. The system uses VRA-GlcNAc as the substrate to generate a chromogen under the catalysis of NAG. A portable device then releases an alkaline catalyst after a programmed delay to initiate color development, followed by optical quantitative analysis. This method provides a linear detection range of 0-200 U/L, with a detection limit of 0.524 U/L and high reproducibility (CV < 6%, <i>n</i> = 5). In a methodological comparison involving 70 clinical urine samples, the SeDR-PAD platform demonstrated strong concordance with the standard clinical method, with a correlation coefficient <i>R</i><sup>2</sup> of 0.9833. These findings highlight the strong potential of SeDR-PAD for clinical POCT of uNAG in individuals at high risk for kidney disease.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-11-24
DOI
https://doi.org/10.1021/acssensors.5c02754
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Sequential Dual-Reagent Paper-Based Analytical Device with Structural Release Control for Point-of-Care Detection of Urinary N -Acetyl-β- d -Glucosaminidase

Jinhong Guo, Jiasheng Yan, Peihong Xiao, Honghua Hu et al.
ACS Sensors
Biosensors and Analytical Detection
article

A Sequential Dual-Reagent Paper-Based Analytical Device with Structural Release Control for Point-of-Care Detection of Urinary N -Acetyl-β- d -Glucosaminidase

Jinhong Guo, Jiasheng Yan, Peihong Xiao, Honghua Hu, Meiling Jin, Hua Wang Shi, Zhengkang Chu, Jie Cheng, Yongmei Tian, Taiqiang Zhao
article en

Abstract

<i>N</i>-acetyl-β-<i>d</i>-glucosaminidase (NAG) is an important biomarker that indicates early renal tubular damage. Its activity level in urine has been widely used for early detection and monitoring of chronic kidney disease (CKD), particularly diabetic nephropathy. However, current detection methods rely on complex instrumentation, which hinders their suitability for point-of-care testing (POCT) that requires portability and user-friendliness. To address this challenge, we developed a sequential dual-reagent paper-based analytical device (SeDR-PAD) that utilizes structural partitioning and a delayed-trigger mechanism to achieve time-programmed control of the NAG enzymatic reaction and color development process. The system uses VRA-GlcNAc as the substrate to generate a chromogen under the catalysis of NAG. A portable device then releases an alkaline catalyst after a programmed delay to initiate color development, followed by optical quantitative analysis. This method provides a linear detection range of 0-200 U/L, with a detection limit of 0.524 U/L and high reproducibility (CV < 6%, <i>n</i> = 5). In a methodological comparison involving 70 clinical urine samples, the SeDR-PAD platform demonstrated strong concordance with the standard clinical method, with a correlation coefficient <i>R</i><sup>2</sup> of 0.9833. These findings highlight the strong potential of SeDR-PAD for clinical POCT of uNAG in individuals at high risk for kidney disease.

ACS SensorsVol. 11(1)
Capital University (US), University of Electronic Science and Technology of China (CN), Shanghai Jiao Tong University (CN), Capital Medical University (CN), Beijing Chao-Yang Hospital, Capital Medical University (CN), CS Diagnostics (DE), Sichuan Center for Disease Control and Prevention (CN), Chongqing Medical University (CN)
Openalex Percentile: Top 65%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.