Assessing Indoor Air Quality in a Chicago Sports Center Using Low-Cost Sensors

Abstract Indoor air quality (IAQ) is a critical public health concern, especially in sports facilities where high occupancy and physical activity increase exposure risks. This study assessed IAQ in a Chicago sports center using low-cost Air Quality Egg sensors, deployed in the basketball courts, rock-climbing area, and weight room from 14 March to 2 April 2024, followed by a colocation test to ensure sensor consistency. Results showed PM 2.5 concentrations across all locations remained below the World Health Organization’s 24-h guideline of 15 µg m −3 but demonstrated distinct diurnal patterns associated with occupancy levels. Indoor PM 2.5 was positively associated with CO 2 and relative humidity (RH), while temperature effects varied by location. Multiple regression models using CO 2 , RH, and temperature explained 34% of PM 2.5 variability, with CO 2 being the strongest predictor. Infiltration analysis showed weak correlations ( R 2 = 0.04) between indoor and outdoor PM 2.5 , indicating that indoor sources were dominant and the building was relatively well sealed. The estimated infiltration coefficients ranged from 0.07 to 0.12, and indoor-generated PM 2.5 levels (1.11–1.66 µg m⁻ 3 ) were relatively lower than those reported in similar buildings. Among the three locations, the weight room recorded the highest levels of PM 2.5 , CO 2 , and RH during both peak and evening hours, despite having the highest air exchange rate based on CO 2 decay analysis. The findings suggest that enhanced ventilation may still be needed to improve IAQ in the weight room. This study demonstrates the utility of low-cost sensors in capturing spatial and temporal IAQ variability. The results emphasize the importance of aligning ventilation strategies with space usage in recreational environments. Graphical Abstract

Authors

Institutions

Publication Details

Journal
Aerosol and Air Quality Research
Published
2025-11-24
DOI
https://doi.org/10.1007/s44408-025-00076-0
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Indoor Air Quality in a Chicago Sports Center Using Low-Cost Sensors

J. W. Post, Ping Jing, Lauren Schmidt, Mohit Chopra et al.
Aerosol and Air Quality Research
Air Quality Monitoring and Forecasting
article

Assessing Indoor Air Quality in a Chicago Sports Center Using Low-Cost Sensors

J. W. Post, Ping Jing, Lauren Schmidt, Mohit Chopra, Amanda Olson, Mena C. R. Whalen, Nicolas Fernandez Rodriguez
article en

Abstract

Abstract Indoor air quality (IAQ) is a critical public health concern, especially in sports facilities where high occupancy and physical activity increase exposure risks. This study assessed IAQ in a Chicago sports center using low-cost Air Quality Egg sensors, deployed in the basketball courts, rock-climbing area, and weight room from 14 March to 2 April 2024, followed by a colocation test to ensure sensor consistency. Results showed PM 2.5 concentrations across all locations remained below the World Health Organization’s 24-h guideline of 15 µg m −3 but demonstrated distinct diurnal patterns associated with occupancy levels. Indoor PM 2.5 was positively associated with CO 2 and relative humidity (RH), while temperature effects varied by location. Multiple regression models using CO 2 , RH, and temperature explained 34% of PM 2.5 variability, with CO 2 being the strongest predictor. Infiltration analysis showed weak correlations ( R 2 = 0.04) between indoor and outdoor PM 2.5 , indicating that indoor sources were dominant and the building was relatively well sealed. The estimated infiltration coefficients ranged from 0.07 to 0.12, and indoor-generated PM 2.5 levels (1.11–1.66 µg m⁻ 3 ) were relatively lower than those reported in similar buildings. Among the three locations, the weight room recorded the highest levels of PM 2.5 , CO 2 , and RH during both peak and evening hours, despite having the highest air exchange rate based on CO 2 decay analysis. The findings suggest that enhanced ventilation may still be needed to improve IAQ in the weight room. This study demonstrates the utility of low-cost sensors in capturing spatial and temporal IAQ variability. The results emphasize the importance of aligning ventilation strategies with space usage in recreational environments. Graphical Abstract

Aerosol and Air Quality ResearchVol. 25(12)
Loyola University Chicago (US)
National Science Foundation
Openalex Percentile: Top 66%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.