Rescaling pMBRT plans for uniform target dose

Proton minibeam radiation therapy (pMBRT) is an emerging modality aimed at improving tumor control while minimizing damage to surrounding healthy tissues. Using a mechanical collimator is one of the most practical and widely used technique to generate a desired pMBRT dose distribution. However, while collimators facilitate beam shaping, they also introduce unwanted dose inhomogeneities in the target, which requires rescaling of spots' weight (Monitor Unit) to ensure uniform dose delivery. Obtaining a homogeneous target dose in pMBRT can simplify evaluation and comparison with conventional radiotherapy. In this study, we present a combined transverse and longitudinal rescaling method to enhance dose uniformity in pMBRT. Our rescaling algorithm adjusts spot weights based on proton energy and lateral position, using data from Geant4 Monte Carlo simulations to quantify dose profiles for each energy layer, both with and without a collimator. The rescaling factors derived from these simulations are applied to correct the dose inhomogeneities introduced by the collimator. Our results demonstrate that while individual rescaling in either the transverse or longitudinal direction can improve the dose distribution, neither alone is sufficient to meet clinical standards. The fully optimized plan, which incorporates both transverse and longitudinal adjustments, achieves a uniform dose distribution within the planning target volume. The final dose lies within the clinically acceptable range of 95%-107%, with significant improvements in dose homogeneity. Additionally, dose-volume histogram and flatness analysis confirm that combined rescaling are necessary to ensure uniform dose coverage.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-11-24
DOI
https://doi.org/10.1088/1361-6560/ae237f
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rescaling pMBRT plans for uniform target dose

Fardous Reaz, Niels Bassler
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
article

Rescaling pMBRT plans for uniform target dose

Fardous Reaz, Niels Bassler
article en

Abstract

Proton minibeam radiation therapy (pMBRT) is an emerging modality aimed at improving tumor control while minimizing damage to surrounding healthy tissues. Using a mechanical collimator is one of the most practical and widely used technique to generate a desired pMBRT dose distribution. However, while collimators facilitate beam shaping, they also introduce unwanted dose inhomogeneities in the target, which requires rescaling of spots' weight (Monitor Unit) to ensure uniform dose delivery. Obtaining a homogeneous target dose in pMBRT can simplify evaluation and comparison with conventional radiotherapy. In this study, we present a combined transverse and longitudinal rescaling method to enhance dose uniformity in pMBRT. Our rescaling algorithm adjusts spot weights based on proton energy and lateral position, using data from Geant4 Monte Carlo simulations to quantify dose profiles for each energy layer, both with and without a collimator. The rescaling factors derived from these simulations are applied to correct the dose inhomogeneities introduced by the collimator. Our results demonstrate that while individual rescaling in either the transverse or longitudinal direction can improve the dose distribution, neither alone is sufficient to meet clinical standards. The fully optimized plan, which incorporates both transverse and longitudinal adjustments, achieves a uniform dose distribution within the planning target volume. The final dose lies within the clinically acceptable range of 95%-107%, with significant improvements in dose homogeneity. Additionally, dose-volume histogram and flatness analysis confirm that combined rescaling are necessary to ensure uniform dose coverage.

Physics in Medicine and BiologyVol. 70(23)
Aarhus University (DK), Aarhus University Hospital (DK)
Openalex Percentile: Top 49%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.