Failure mechanism and hysteresis performance assessment of concrete-filled double-plate steel composite shear walls

This study investigates the current research gap in accurately predicting the cyclic hysteretic behavior of concrete-filled double-plate (CFDP) steel composite shear walls, for which existing numerical approaches often neglect passive confinement effects, cyclic steel hardening, and progressive concrete damage. Unlike previous studies that primarily rely on simplified constitutive models or monotonic loading, this work develops a detailed micro-finite element (MFE) hysteresis model in ABAQUS that explicitly captures local buckling, concrete cracking and crushing, unloading stiffness degradation, and the Bauschinger effect. The proposed model employs the Concrete Damaged Plasticity (CDP) formulation for confined concrete and a hybrid isotropic-kinematic hardening rule for steel, enabling realistic simulation of cyclic pinching and material degradation. Validation against experimental results demonstrates excellent agreement, with an average base-shear prediction error of only 1.6 %, confirming the model’s reliability. A comprehensive parametric study quantifies, for the first time, the coupled influence of wall aspect ratio and concrete compressive strength on seismic performance indicators including yield and ultimate strength, stiffness deterioration, ductility, cumulative energy dissipation, and equivalent viscous damping ratio. Results show that lower aspect ratios significantly enhance cyclic energy dissipation and ductility, whereas higher concrete strengths increase initial stiffness and peak lateral resistance. Equivalent viscous damping ratios of 25–33 % shown the superior hysteretic energy absorption of CFDP walls. This study provides failure analysis and preventive insights, aligning with focus on failure mechanisms, risk mitigation, and structural integrity in seismic design.

Authors

Publication Details

Journal
Structures
Published
2025-11-24
DOI
https://doi.org/10.1016/j.istruc.2025.110675
Citations
1
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure mechanism and hysteresis performance assessment of concrete-filled double-plate steel composite shear walls

Hojatallah Azarkhosh, Mojtaba Gorji Azandariani, Majid Pouraminian, Hossein Parvini Sani et al.
1 citations
Structures
Seismic Performance and Analysis
0.95
article

Failure mechanism and hysteresis performance assessment of concrete-filled double-plate steel composite shear walls

Hojatallah Azarkhosh, Mojtaba Gorji Azandariani, Majid Pouraminian, Hossein Parvini Sani, Ali Parvizi, Seyyed Behnam Beheshti
article en
1 citations

Abstract

This study investigates the current research gap in accurately predicting the cyclic hysteretic behavior of concrete-filled double-plate (CFDP) steel composite shear walls, for which existing numerical approaches often neglect passive confinement effects, cyclic steel hardening, and progressive concrete damage. Unlike previous studies that primarily rely on simplified constitutive models or monotonic loading, this work develops a detailed micro-finite element (MFE) hysteresis model in ABAQUS that explicitly captures local buckling, concrete cracking and crushing, unloading stiffness degradation, and the Bauschinger effect. The proposed model employs the Concrete Damaged Plasticity (CDP) formulation for confined concrete and a hybrid isotropic-kinematic hardening rule for steel, enabling realistic simulation of cyclic pinching and material degradation. Validation against experimental results demonstrates excellent agreement, with an average base-shear prediction error of only 1.6 %, confirming the model’s reliability. A comprehensive parametric study quantifies, for the first time, the coupled influence of wall aspect ratio and concrete compressive strength on seismic performance indicators including yield and ultimate strength, stiffness deterioration, ductility, cumulative energy dissipation, and equivalent viscous damping ratio. Results show that lower aspect ratios significantly enhance cyclic energy dissipation and ductility, whereas higher concrete strengths increase initial stiffness and peak lateral resistance. Equivalent viscous damping ratios of 25–33 % shown the superior hysteretic energy absorption of CFDP walls. This study provides failure analysis and preventive insights, aligning with focus on failure mechanisms, risk mitigation, and structural integrity in seismic design.

StructuresVol. 82
Openalex Percentile: Top 19%
Seismic Performance and Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Failure mechanism and hysteresis performance assessment of concrete-filled double-plate steel composite shear walls — Hojatallah Azarkhosh, Mojtaba Gorji Azandariani, et al. · Structures (2025) | TGRS Research Map | TGRS