One-Pot Photocontrolled CRISPR-Cas12b Coupled with Loop-Mediated Isothermal Amplification Assay for Point-of-Care Test of <i>Mycoplasma pneumonia</i>

<i>Mycoplasma pneumoniae</i> (MP) is a highly prevalent respiratory pathogen, making the development of point-of-care testing (POCT) methods for its detection essential. The integration of loop-mediated isothermal amplification (LAMP) with CRISPR-Cas12b systems demonstrates remarkable specificity and offers promising potential for MP POCT application. However, the current one-pot LAMP/CRISPR-Cas12b system (HOLMESv2) faces the challenge of low sensitivity due to the premature cleavage of the template by CRISPR, which limits its practical utility. To address this, this study introduces a photocontrolled HOLMESv2 (pHOLMESv2) assay using gRNA with an NPOM-modified spacer region. This modification prevents full base pairing between the gRNA and MP DNA, thereby keeping the CRISPR-Cas12b system in an inactive condition during the LAMP reaction and avoiding unintended cleavage of the DNA template. After completion of the LAMP reaction, light irradiation eliminates the NPOM group from the gRNA, restoring its activity to cleave the LAMP products, resulting in a fluorescence signal. The pHOLMESv2 assay successfully addresses the issue of premature DNA template cleavage, improving the limit of detection (LoD) by 133-fold (7.5 copies/μL). Additionally, this method enables direct detection of samples treated with nucleic acid release agents, eliminating the need for complex extraction, and features lyophilized reagents for enhanced stability, storage, and transport. The efficacy of pHOLMESv2 was assessed with 160 clinical MP samples, achieving a sensitivity of 99.0% and a specificity of 100.0%. The pHOLMESv2 assay, when combined with the developed smartphone-based amplification reader, provides a highly sensitive, specific, portable, and cost-effective MP detection, indicating its potential for significant diagnostic use.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-11-24
DOI
https://doi.org/10.1021/acssensors.5c01679
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-Pot Photocontrolled CRISPR-Cas12b Coupled with Loop-Mediated Isothermal Amplification Assay for Point-of-Care Test of Mycoplasma pneumonia

E. Costa, Qiangqiang Fu, Lizhi Yan, Jiayu Feng et al.
2 citations
ACS Sensors
Biosensors and Analytical Detection
1.35
article

One-Pot Photocontrolled CRISPR-Cas12b Coupled with Loop-Mediated Isothermal Amplification Assay for Point-of-Care Test of Mycoplasma pneumonia

E. Costa, Qiangqiang Fu, Lizhi Yan, Jiayu Feng, Yongyu Rui, Fei‐Fei Jin, Lei Zheng, Quan Liu, Zhen Cai, Tao Qi, Wenwen Chen, Wenjie Zhong, Ze Wu, Wenhui Zhu
article en
2 citations

Abstract

<i>Mycoplasma pneumoniae</i> (MP) is a highly prevalent respiratory pathogen, making the development of point-of-care testing (POCT) methods for its detection essential. The integration of loop-mediated isothermal amplification (LAMP) with CRISPR-Cas12b systems demonstrates remarkable specificity and offers promising potential for MP POCT application. However, the current one-pot LAMP/CRISPR-Cas12b system (HOLMESv2) faces the challenge of low sensitivity due to the premature cleavage of the template by CRISPR, which limits its practical utility. To address this, this study introduces a photocontrolled HOLMESv2 (pHOLMESv2) assay using gRNA with an NPOM-modified spacer region. This modification prevents full base pairing between the gRNA and MP DNA, thereby keeping the CRISPR-Cas12b system in an inactive condition during the LAMP reaction and avoiding unintended cleavage of the DNA template. After completion of the LAMP reaction, light irradiation eliminates the NPOM group from the gRNA, restoring its activity to cleave the LAMP products, resulting in a fluorescence signal. The pHOLMESv2 assay successfully addresses the issue of premature DNA template cleavage, improving the limit of detection (LoD) by 133-fold (7.5 copies/μL). Additionally, this method enables direct detection of samples treated with nucleic acid release agents, eliminating the need for complex extraction, and features lyophilized reagents for enhanced stability, storage, and transport. The efficacy of pHOLMESv2 was assessed with 160 clinical MP samples, achieving a sensitivity of 99.0% and a specificity of 100.0%. The pHOLMESv2 assay, when combined with the developed smartphone-based amplification reader, provides a highly sensitive, specific, portable, and cost-effective MP detection, indicating its potential for significant diagnostic use.

ACS SensorsVol. 10(12)
National Center for Injury Prevention and Control (US), Biotechnology Research Center (IR), Key Laboratory of Guangdong Province (CN), Nanfang Hospital (CN), Shenzhen Luohu People's Hospital (CN), Guangdong Provincial Center for Disease Control and Prevention (CN), Guangdong Provincial People's Hospital (CN), Advanced Laser Technology (United Kingdom) (GB), Southern Medical University (CN)
Openalex Percentile: Top 17%
Biosensors and Analytical Detection
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.