InAlN/GaN Detectors for Real-Time Dosimetry in Ultra-High Dose Rate FLASH Radiotherapy

This letter reports the first characterization of InAlN/GaN-on-Si solid-state detectors under ultra-high dose-per-pulse (UH-DPP) electron irradiation for FLASH radiotherapy applications. Unpassivated Ni/Au metal-semiconductor-metal (MSM) and two-dimensional electron gas (2DEG) interdigital transducer (IDT) detectors exhibited the best transient performance, with the 2DEG IDT resolving individual pulses as short as 3 μs rise and 325 μs fall times and achieving a signal-to-noise ratio (SNR) exceeding 220 under 2 Gy pulses. Across a dose-per-pulse (DPP) range of 0.05-0.5 Gy, the 2DEG IDT detector demonstrated consistent, dose-dependent voltage responses with sensitivities of 0.5-0.9 V/Gy and a normalized sensitivity of 48.75 nC/Gy/mm<sup>2</sup>, one to two orders of magnitude higher than reported SiC and diamond detectors. These results establish InAlN/GaN detectors as promising candidates for compact, high-speed, and radiation-tolerant dosimetry systems capable of real-time single-pulse monitoring in clinical FLASH radiotherapy.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-11-24
DOI
https://doi.org/10.1109/lsens.2025.3636392
Primary Topic
GaN-based semiconductor devices and materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

InAlN/GaN Detectors for Real-Time Dosimetry in Ultra-High Dose Rate FLASH Radiotherapy

Guy Garty, Yi-Chen Liu, Michael Bardash, Si‐Young Choi et al.
IEEE Sensors Letters
GaN-based semiconductor devices and materials
article

InAlN/GaN Detectors for Real-Time Dosimetry in Ultra-High Dose Rate FLASH Radiotherapy

Guy Garty, Yi-Chen Liu, Michael Bardash, Si‐Young Choi, Kevin Dai, Andrew Harken, Ioannis Kymissis, Peter Ballentine, Ilaria Fratelli, Yuewen Tan, Savannah R. Eisner, Carryn M. Anderson
article en

Abstract

This letter reports the first characterization of InAlN/GaN-on-Si solid-state detectors under ultra-high dose-per-pulse (UH-DPP) electron irradiation for FLASH radiotherapy applications. Unpassivated Ni/Au metal-semiconductor-metal (MSM) and two-dimensional electron gas (2DEG) interdigital transducer (IDT) detectors exhibited the best transient performance, with the 2DEG IDT resolving individual pulses as short as 3 μs rise and 325 μs fall times and achieving a signal-to-noise ratio (SNR) exceeding 220 under 2 Gy pulses. Across a dose-per-pulse (DPP) range of 0.05-0.5 Gy, the 2DEG IDT detector demonstrated consistent, dose-dependent voltage responses with sensitivities of 0.5-0.9 V/Gy and a normalized sensitivity of 48.75 nC/Gy/mm<sup>2</sup>, one to two orders of magnitude higher than reported SiC and diamond detectors. These results establish InAlN/GaN detectors as promising candidates for compact, high-speed, and radiation-tolerant dosimetry systems capable of real-time single-pulse monitoring in clinical FLASH radiotherapy.

IEEE Sensors LettersVol. 10(1)
University of Illinois Urbana-Champaign (US), Osservatorio astronomico di Bologna (IT), Detector Technology (United States) (US), Columbia University (US), University of Bologna (IT)
Openalex Percentile: Top 77%
GaN-based semiconductor devices and materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.