Experimental verification of electrode activation for improved performance in vanadium redox flow batteries

Vanadium redox flow batteries (VRFBs) have held significant promise in large-scale energy storage applications due to their advantages, including long cycle life, high safety, and the ability to independently design power and capacity. However, the relatively low power density has remained a critical bottleneck for further development. As a key material in VRFB power units, enhancing the performance of graphite felt electrodes has represented an effective strategy for achieving high-power battery technology. To improve the activity of graphite felt electrodes, this study has employed an experimental verification approach to investigate battery performance parameters under various activation temperatures and durations, thereby identifying the optimal activation conditions. In contrast to prior studies that exclusively targeted 400°C without systematically optimizing activation duration, this study has systematically evaluated five activation temperatures and four activation durations to clarify the synergistic influence of these parameters on VRFB performance. Specifically, experiments have been conducted at room temperature using activation temperatures of 300, 350, 400, 450, and 500°C, as well as activation durations of 24, 11, 7, and 3 ​h. The results have indicated that an activation temperature of 400°C yielded notable improvements in charge/discharge performance, internal resistance, efficiency, and capacity retention. Notably, energy efficiency has increased by 5.06%, 5.94%, 3.67%, and 4.72% under these conditions. This study has identified the optimal activation conditions of “400°C for 7 ​h” and has provided the corresponding performance data, which can help reduce research costs associated with electrode activation in future investigations. This study has provided valuable insights into electrode activation and has offered guidance for enhancing VRFB performance. • Determine the optimal temperature and duration for thermal activation through systematic experimentation. • Evaluate the variations in battery performance at the optimal activation temperature. • Investigated the coupling mechanism between electrode thermal activation and battery performance.

Authors

Publication Details

Journal
Green Energy and Resources
Published
2025-11-24
DOI
https://doi.org/10.1016/j.gerr.2025.100155
Primary Topic
Advanced battery technologies research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental verification of electrode activation for improved performance in vanadium redox flow batteries

Longxing Wu, Osamah Ibrahim Khalaf, Zebo Huang, Zhi Zhuge
Green Energy and Resources
Advanced battery technologies research
article

Experimental verification of electrode activation for improved performance in vanadium redox flow batteries

Longxing Wu, Osamah Ibrahim Khalaf, Zebo Huang, Zhi Zhuge
article en

Abstract

Vanadium redox flow batteries (VRFBs) have held significant promise in large-scale energy storage applications due to their advantages, including long cycle life, high safety, and the ability to independently design power and capacity. However, the relatively low power density has remained a critical bottleneck for further development. As a key material in VRFB power units, enhancing the performance of graphite felt electrodes has represented an effective strategy for achieving high-power battery technology. To improve the activity of graphite felt electrodes, this study has employed an experimental verification approach to investigate battery performance parameters under various activation temperatures and durations, thereby identifying the optimal activation conditions. In contrast to prior studies that exclusively targeted 400°C without systematically optimizing activation duration, this study has systematically evaluated five activation temperatures and four activation durations to clarify the synergistic influence of these parameters on VRFB performance. Specifically, experiments have been conducted at room temperature using activation temperatures of 300, 350, 400, 450, and 500°C, as well as activation durations of 24, 11, 7, and 3 ​h. The results have indicated that an activation temperature of 400°C yielded notable improvements in charge/discharge performance, internal resistance, efficiency, and capacity retention. Notably, energy efficiency has increased by 5.06%, 5.94%, 3.67%, and 4.72% under these conditions. This study has identified the optimal activation conditions of “400°C for 7 ​h” and has provided the corresponding performance data, which can help reduce research costs associated with electrode activation in future investigations. This study has provided valuable insights into electrode activation and has offered guidance for enhancing VRFB performance. • Determine the optimal temperature and duration for thermal activation through systematic experimentation. • Evaluate the variations in battery performance at the optimal activation temperature. • Investigated the coupling mechanism between electrode thermal activation and battery performance.

Green Energy and ResourcesVol. 3(4)
Openalex Percentile: Top 64%
Advanced battery technologies research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.