A bicentric study on the application of dual energy CT for predicting hemorrhagic transformation post endovascular thrombectomy

Hemorrhagic transformation (HT) critically impacts outcomes in acute ischemic stroke (AIS) patients post-endovascular thrombectomy (EVT). Building upon the validated utility of post-EVT dual-energy CT (DECT), this study focused on developing and integrating a DECT-based predictive model with key clinical variables to achieve precise, individualized quantification of HT risk. This retrospective study analyzed 116 thrombectomy treated AIS patients stratified by HT status. Post-EVT DECT within 24 h assessed CT values (in Hounsfield Units, HU) of ischemic lesions on mixed energy images; CT values (in HU) on virtual non-contrast (VNC) images and on Sn80 keV and Sn150 keV monoenergetic images; absolute iodine concentrations (AIC, in mg/mL); and relative iodine concentrations (RIC, in %, where RIC = lesion AIC/sigmoid sinus AIC), using follow-up imaging and clinical criteria as the gold standard for HT.. HT patients exhibited higher NIHSS (median 14.5 vs. 9.0) and lower ASPECTS (9 vs. 13) than non-HT (nHT) counterparts, with elevated glucose (GLU, 8.26 vs. 6.45 mmol/L) and lower systolic blood pressure (SBP, 147.5 vs. 156.5 mmHg) (all P < 0.050). DECT-derived parameters demonstrated diagnostic utility, with both iodine overlay maps (IOM) and VNC positivity (χ<sup>2</sup> = 60.331, P < 0.001) and dual negativity (χ<sup>2</sup> = 58.870, P < 0.001) showing significant intergroup discrimination. Among 42 patients with IOM hyperdensity, RIC differed significantly between subgroups (t = - 2.566, P = 0.014), with elevated RIC independently associated with HT risk (OR = 1.040, 95% CI 1.003-1.078; P = 0.034). RIC alone exhibited strong predictive capacity for HT (AUC = 0.890, 95% CI 0.822-0.957). A nomogram-based model incorporating NIHSS, ASPECTS, and RIC achieved excellent HT prediction in both training (AUC = 0.947, 95% CI 0.903-0.991) and validation cohorts (AUC = 0.902, 95% CI 0.786-1.000), with stable calibration (training: P = 0.655; validation: P = 0.175) and clinical utility on decision curve analysis. Integration into stroke protocols may guide anticoagulation and secondary prevention decisions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-24
DOI
https://doi.org/10.1038/s41598-025-25574-4
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A bicentric study on the application of dual energy CT for predicting hemorrhagic transformation post endovascular thrombectomy

Da-peng Mo, Yinping Dong, Guangrui Yang, Yun-Shan Tan et al.
Scientific Reports
Advanced X-ray and CT Imaging
article

A bicentric study on the application of dual energy CT for predicting hemorrhagic transformation post endovascular thrombectomy

Da-peng Mo, Yinping Dong, Guangrui Yang, Yun-Shan Tan, Ding‐Shinn Chen, C. Liu, Gangming Zhu, Rongrong Zhu, X Y Feng, Shourui Yang, Nuo Chen, Xing Liang, Z. Fu, Tao Xu, Zhilong Lin, Weike Su
article en

Abstract

Hemorrhagic transformation (HT) critically impacts outcomes in acute ischemic stroke (AIS) patients post-endovascular thrombectomy (EVT). Building upon the validated utility of post-EVT dual-energy CT (DECT), this study focused on developing and integrating a DECT-based predictive model with key clinical variables to achieve precise, individualized quantification of HT risk. This retrospective study analyzed 116 thrombectomy treated AIS patients stratified by HT status. Post-EVT DECT within 24 h assessed CT values (in Hounsfield Units, HU) of ischemic lesions on mixed energy images; CT values (in HU) on virtual non-contrast (VNC) images and on Sn80 keV and Sn150 keV monoenergetic images; absolute iodine concentrations (AIC, in mg/mL); and relative iodine concentrations (RIC, in %, where RIC = lesion AIC/sigmoid sinus AIC), using follow-up imaging and clinical criteria as the gold standard for HT.. HT patients exhibited higher NIHSS (median 14.5 vs. 9.0) and lower ASPECTS (9 vs. 13) than non-HT (nHT) counterparts, with elevated glucose (GLU, 8.26 vs. 6.45 mmol/L) and lower systolic blood pressure (SBP, 147.5 vs. 156.5 mmHg) (all P < 0.050). DECT-derived parameters demonstrated diagnostic utility, with both iodine overlay maps (IOM) and VNC positivity (χ<sup>2</sup> = 60.331, P < 0.001) and dual negativity (χ<sup>2</sup> = 58.870, P < 0.001) showing significant intergroup discrimination. Among 42 patients with IOM hyperdensity, RIC differed significantly between subgroups (t = - 2.566, P = 0.014), with elevated RIC independently associated with HT risk (OR = 1.040, 95% CI 1.003-1.078; P = 0.034). RIC alone exhibited strong predictive capacity for HT (AUC = 0.890, 95% CI 0.822-0.957). A nomogram-based model incorporating NIHSS, ASPECTS, and RIC achieved excellent HT prediction in both training (AUC = 0.947, 95% CI 0.903-0.991) and validation cohorts (AUC = 0.902, 95% CI 0.786-1.000), with stable calibration (training: P = 0.655; validation: P = 0.175) and clinical utility on decision curve analysis. Integration into stroke protocols may guide anticoagulation and secondary prevention decisions.

Scientific ReportsVol. 15(1)
Guangdong Medical College (CN), Tung Wah Hospital (CN), Songshan Lake Materials Laboratory (CN), Dongguan People’s Hospital (CN)
Openalex Percentile: Top 65%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.