Clinical usability and functional outcomes of a lightweight robotic orthosis (HKAFO) in chronic stroke patients with hemiplegic gait: a pilot study

Gait impairment after stroke limits independence. Powered orthoses may augment task-specific over-ground practice, although clinical uptake is constrained by usability. We evaluated a powered hip–knee–ankle–foot orthosis (HKAFO) for functional outcomes and usability in ambulatory adults with chronic post-stroke hemiparesis. In a prospective multicenter single-arm pilot, 15 participants completed six supervised over-ground HKAFO sessions across three weeks (40 min per session). Pre-specified clinical outcomes were the Berg Balance Scale (BBS), Dynamic Gait Index (DGI), and Timed Up and Go (TUG). Short-distance walking (6-minute walk test [6MWT], 10-meter walk test [10MWT]) was assessed with and without the device. Analyses used paired tests and a two-way repeated-measures ANOVA with within-subject factors Time (pre, post) and Condition (with HKAFO, without HKAFO). BBS increased by 3 points (45 [36–49] to 48 [42–52], p = 0.002), DGI by 2 points (19 [13–21] to 21 [18–23], p = 0.004), and TUG decreased by 1.98 s (16.80 [11.35–21.65] to 14.82 [9.85–20.39], p = 0.014). With the HKAFO, 6MWT distance rose (194.1 to 220.0 m, p = 0.006) and 10MWT speed increased (0.57 to 0.71 m/s, p = 0.005), whereas unassisted walking changed little over three weeks. Two-way repeated-measures ANOVA confirmed a main effect of Time and a strong main effect of Condition for 6MWT (Time: F(1,14) = 10.34, p = 0.006, ηp²=0.425; Condition: F(1,14) = 33.93, p < 0.001, ηp²=0.708), with a non-significant Time×Condition interaction (p = 0.090). For 10MWT cadence the interaction approached significance (F(1,14) = 4.23, p = 0.059, ηp²=0.232); for 10MWT speed and time, interactions were not significant, while the Condition main effect remained significant (speed: F(1,14) = 17.15, p = 0.010; time: F(1,14) = 7.46, p = 0.016). Participants reported perceived stability benefits alongside burdens related to weight, donning and doffing, and operation. Across six sessions, HKAFO-assisted over-ground practice was associated with improved balance and functional mobility and with faster short-distance gait during device-assisted walking, with limited short-term transfer to unassisted gait. The two-condition design delineated a device-dependent profile. Confirmatory randomized trials with longer follow-up and usability-focused refinement are warranted.

Authors

Institutions

Publication Details

Journal
Journal of NeuroEngineering and Rehabilitation
Published
2025-11-24
DOI
https://doi.org/10.1186/s12984-025-01770-1
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical usability and functional outcomes of a lightweight robotic orthosis (HKAFO) in chronic stroke patients with hemiplegic gait: a pilot study

H.S. Cho, Yeo Joon Yun, Dongbin Shin, Hyeyoun Jang et al.
Journal of NeuroEngineering and Rehabilitation
Prosthetics and Rehabilitation Robotics
article

Clinical usability and functional outcomes of a lightweight robotic orthosis (HKAFO) in chronic stroke patients with hemiplegic gait: a pilot study

H.S. Cho, Yeo Joon Yun, Dongbin Shin, Hyeyoun Jang, Mi Jung Kim, Hyuk-Jae Choi, Bo Kyoung Kim
article en

Abstract

Gait impairment after stroke limits independence. Powered orthoses may augment task-specific over-ground practice, although clinical uptake is constrained by usability. We evaluated a powered hip–knee–ankle–foot orthosis (HKAFO) for functional outcomes and usability in ambulatory adults with chronic post-stroke hemiparesis. In a prospective multicenter single-arm pilot, 15 participants completed six supervised over-ground HKAFO sessions across three weeks (40 min per session). Pre-specified clinical outcomes were the Berg Balance Scale (BBS), Dynamic Gait Index (DGI), and Timed Up and Go (TUG). Short-distance walking (6-minute walk test [6MWT], 10-meter walk test [10MWT]) was assessed with and without the device. Analyses used paired tests and a two-way repeated-measures ANOVA with within-subject factors Time (pre, post) and Condition (with HKAFO, without HKAFO). BBS increased by 3 points (45 [36–49] to 48 [42–52], p = 0.002), DGI by 2 points (19 [13–21] to 21 [18–23], p = 0.004), and TUG decreased by 1.98 s (16.80 [11.35–21.65] to 14.82 [9.85–20.39], p = 0.014). With the HKAFO, 6MWT distance rose (194.1 to 220.0 m, p = 0.006) and 10MWT speed increased (0.57 to 0.71 m/s, p = 0.005), whereas unassisted walking changed little over three weeks. Two-way repeated-measures ANOVA confirmed a main effect of Time and a strong main effect of Condition for 6MWT (Time: F(1,14) = 10.34, p = 0.006, ηp²=0.425; Condition: F(1,14) = 33.93, p < 0.001, ηp²=0.708), with a non-significant Time×Condition interaction (p = 0.090). For 10MWT cadence the interaction approached significance (F(1,14) = 4.23, p = 0.059, ηp²=0.232); for 10MWT speed and time, interactions were not significant, while the Condition main effect remained significant (speed: F(1,14) = 17.15, p = 0.010; time: F(1,14) = 7.46, p = 0.016). Participants reported perceived stability benefits alongside burdens related to weight, donning and doffing, and operation. Across six sessions, HKAFO-assisted over-ground practice was associated with improved balance and functional mobility and with faster short-distance gait during device-assisted walking, with limited short-term transfer to unassisted gait. The two-condition design delineated a device-dependent profile. Confirmatory randomized trials with longer follow-up and usability-focused refinement are warranted.

Journal of NeuroEngineering and RehabilitationVol. 22(1)
Hanyang University Guri Hospital (KR), Korea Institute of Public Finance (KR), National Rehabilitation Center (KR), Hanyang University Seoul Hospital (KR), DNACARE (South Korea) (KR), Hanyang University Medical Center (KR), Hanyang University (KR), Anyang University (KR)
Korea Medical Device Development Fund, Hanyang University, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea, Institute for Information and Communications Technology Promotion
Openalex Percentile: Top 65%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.