Evaluation of the V-gel® Advanced Supraglottic Airway Device Across Different Ventilatory Modes in Anaesthetised Cats

Endotracheal intubation in cats carries risks; supraglottic airway devices (SADs) offer a less invasive alternative. This prospective clinical study evaluated the V-gel<sup>®</sup> advanced in cats undergoing ovariohysterectomy, with the primary aim of intra-anaesthetic gas leakage; secondary aims were ease of placement, complications, and the effect of device re-use. Spirometric inspired/expired tidal volumes were recorded under predefined ventilatory settings; leakage was calculated and analysed. Of 52 cats enrolled, 47 were analysed. Leakage occurred in 13% during spontaneous breathing and rose to 41.8% with Continuous Positive Airway Pressure (CPAP) 5 cmH<sub>2</sub>O; by contrast, controlled mechanical ventilation showed lower leakage, with the smallest values at Peak Inspiratory Pressure (PIP) of 12 cmH<sub>2</sub>O and 16 cmH<sub>2</sub>O (2.1% and 6.5%, respectively). Re-used devices leaked less than new ones (<i>p</i> = 0.003). Placement by students was straightforward after adequate depth was achieved. Complications included mild regurgitant material in three cats and pulmonary aspiration in two (one euthanised, one discharged after supportive care). The V-gel<sup>®</sup> advanced enabled rapid airway management with leakage influenced by ventilation mode, airway pressure, and device re-use. Findings support cautious use during spontaneous breathing or CPAP, attention to fasting and fresh-gas flows, and further controlled comparisons with prior V-gel<sup>®</sup> models and endotracheal intubation.

Authors

Institutions

Publication Details

Journal
Veterinary Sciences
Published
2025-11-22
DOI
https://doi.org/10.3390/vetsci12121112
Primary Topic
Veterinary Pharmacology and Anesthesia
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the V-gel® Advanced Supraglottic Airway Device Across Different Ventilatory Modes in Anaesthetised Cats

Jaime Viscasillas, José M Gómez-Silvestre, Ariel Cañón, Agustín Martínez Albiñana et al.
Veterinary Sciences
Veterinary Pharmacology and Anesthesia
article

Evaluation of the V-gel® Advanced Supraglottic Airway Device Across Different Ventilatory Modes in Anaesthetised Cats

Jaime Viscasillas, José M Gómez-Silvestre, Ariel Cañón, Agustín Martínez Albiñana, Álvaro Jesús Gutiérrez Bautista, José Ignacio Redondo, Eva Zoe Hernández, Esther Martinez Parrón, Maria de los Reyes Marti-Scharfhausen
article en

Abstract

Endotracheal intubation in cats carries risks; supraglottic airway devices (SADs) offer a less invasive alternative. This prospective clinical study evaluated the V-gel<sup>®</sup> advanced in cats undergoing ovariohysterectomy, with the primary aim of intra-anaesthetic gas leakage; secondary aims were ease of placement, complications, and the effect of device re-use. Spirometric inspired/expired tidal volumes were recorded under predefined ventilatory settings; leakage was calculated and analysed. Of 52 cats enrolled, 47 were analysed. Leakage occurred in 13% during spontaneous breathing and rose to 41.8% with Continuous Positive Airway Pressure (CPAP) 5 cmH<sub>2</sub>O; by contrast, controlled mechanical ventilation showed lower leakage, with the smallest values at Peak Inspiratory Pressure (PIP) of 12 cmH<sub>2</sub>O and 16 cmH<sub>2</sub>O (2.1% and 6.5%, respectively). Re-used devices leaked less than new ones (<i>p</i> = 0.003). Placement by students was straightforward after adequate depth was achieved. Complications included mild regurgitant material in three cats and pulmonary aspiration in two (one euthanised, one discharged after supportive care). The V-gel<sup>®</sup> advanced enabled rapid airway management with leakage influenced by ventilation mode, airway pressure, and device re-use. Findings support cautious use during spontaneous breathing or CPAP, attention to fasting and fresh-gas flows, and further controlled comparisons with prior V-gel<sup>®</sup> models and endotracheal intubation.

Veterinary SciencesVol. 12(12)
University of Pinar del Río (CU), Universidad Cardenal Herrera CEU (ES), Euskadiko Parke Teknologikoa (ES), Vall d'Hebron Institut de Recerca (ES), Menescalia Centro Veterinario (ES), Sulzer (United Kingdom) (GB), University of Edinburgh (GB)
Openalex Percentile: Top 59%
Veterinary Pharmacology and Anesthesia
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.