Ratio Electrochemical Detection of Nitrofurazone Based on Carbon Nanotubes/Electroactive Schiff Base Polymer

Nitrofurazone (NFZ), as an antibiotic, is carcinogenic upon prolonged exposure. Thus, detecting NFZ and its metabolites is essential for ensuring food safety and preventing potential health risks to humans. A dual‐signal electrochemical sensor consisting of a composite of carbon nanotubes and an electroactive Schiff base polymer (SBP Thi‐DHA , synthesized from thionine and 2,5‐dihydroxyterephthalaldehyde)/carbon nanotubes) enabled highly sensitive detection of nitrofurazolidone (NFZ). The sensor was fabricated using 2,5‐dihydroxyterephthalaldehyde (DHA) and electroactive thionine (Thi) monomer as precursors to prepare spherical SBP Thi‐DHA nanomaterials with an average diameter of approximately 2 μm through a Schiff base reaction. The resulting material possessed high surface area, superior electron transport capability, and abundant surface functional groups, which enabled uniform loading of amino‐functionalized carbon nanotubes (NH 2 ‐CNT) and significantly enhanced the catalytic performance and detection sensitivity of the sensor. Empirical evidence demonstrated that the ratiometric electrochemical sensor achieved a remarkably low detection of 4.3 nM for NFZ at a reference signal of −0.6 V, with wide linear ranges of 13.1 nM‐80 and 80–400 μM. The introduction of ratiometric signals effectively minimized interference caused by electrode surface state variations, electrolyte concentration fluctuations, and temperature changes during detection, significantly improving measurement accuracy and reproducibility. Furthermore, the excellent stability of SBP Thi‐DHA /CNT on the electrode surface endowed the sensor with outstanding reusability.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2025-11-01
DOI
https://doi.org/10.1002/elan.70080
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ratio Electrochemical Detection of Nitrofurazone Based on Carbon Nanotubes/Electroactive Schiff Base Polymer

Fugang Xu, Canwei Peng, Xiaomin Zhang, Jianhui Xiong et al.
Electroanalysis
Electrochemical sensors and biosensors
article

Ratio Electrochemical Detection of Nitrofurazone Based on Carbon Nanotubes/Electroactive Schiff Base Polymer

Fugang Xu, Canwei Peng, Xiaomin Zhang, Jianhui Xiong, Wenxiao Jin, L. Miao, Likang Wu
article en

Abstract

Nitrofurazone (NFZ), as an antibiotic, is carcinogenic upon prolonged exposure. Thus, detecting NFZ and its metabolites is essential for ensuring food safety and preventing potential health risks to humans. A dual‐signal electrochemical sensor consisting of a composite of carbon nanotubes and an electroactive Schiff base polymer (SBP Thi‐DHA , synthesized from thionine and 2,5‐dihydroxyterephthalaldehyde)/carbon nanotubes) enabled highly sensitive detection of nitrofurazolidone (NFZ). The sensor was fabricated using 2,5‐dihydroxyterephthalaldehyde (DHA) and electroactive thionine (Thi) monomer as precursors to prepare spherical SBP Thi‐DHA nanomaterials with an average diameter of approximately 2 μm through a Schiff base reaction. The resulting material possessed high surface area, superior electron transport capability, and abundant surface functional groups, which enabled uniform loading of amino‐functionalized carbon nanotubes (NH 2 ‐CNT) and significantly enhanced the catalytic performance and detection sensitivity of the sensor. Empirical evidence demonstrated that the ratiometric electrochemical sensor achieved a remarkably low detection of 4.3 nM for NFZ at a reference signal of −0.6 V, with wide linear ranges of 13.1 nM‐80 and 80–400 μM. The introduction of ratiometric signals effectively minimized interference caused by electrode surface state variations, electrolyte concentration fluctuations, and temperature changes during detection, significantly improving measurement accuracy and reproducibility. Furthermore, the excellent stability of SBP Thi‐DHA /CNT on the electrode surface endowed the sensor with outstanding reusability.

ElectroanalysisVol. 37(11)
Wuhan University (CN), Jiangxi Normal University (CN)
Openalex Percentile: Top 64%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.