Non-Injected broadband impedance estimation based on injected impedance measurement

• A two-stage operational states classification method based on multi-domain features is proposed. • An operational states matching method based on Pearson correlation is proposed. • Non-injected broadband impedance estimation is proposed based on injected impedance measurement. • The accuracy of the harmonic impedance fitting are more than 90% for simulations. As power electronic devices become increasingly connected to power grids, power systems face issues, such as stability and harmonic resonance; broadband harmonic impedance is a key piece of information that helps analyze these issues. This study proposes a non-injected broadband impedance estimation method based on injected method impedance measurement. First, a two-stage operational states classification method was conceived based on multi-domain features. Second, an operational states matching method was proposed to associate the concerned-time power quality monitoring data with the pre-classified states, based on Pearson correlation. Third, a regularized optimization model was developed to estimate the broadband impedance curve. Finally, a grid-connected inverter system under different control strategies was constructed as a case study. The simulations demonstrated that the accuracy of the proposed methodology was more than 90% for all the operational states defined in the case study, thus it obviates the need for perturbation injection as in traditional methods to enable real-time broadband impedance measurement.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-11-01
DOI
https://doi.org/10.1016/j.ijepes.2025.111363
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Injected broadband impedance estimation based on injected impedance measurement

Hao Chen, Peng Zhang, Ying Wang, Shunyi Li et al.
International Journal of Electrical Power & Energy Systems
Power Quality and Harmonics
article

Non-Injected broadband impedance estimation based on injected impedance measurement

Hao Chen, Peng Zhang, Ying Wang, Shunyi Li, Yang Liu
article en

Abstract

• A two-stage operational states classification method based on multi-domain features is proposed. • An operational states matching method based on Pearson correlation is proposed. • Non-injected broadband impedance estimation is proposed based on injected impedance measurement. • The accuracy of the harmonic impedance fitting are more than 90% for simulations. As power electronic devices become increasingly connected to power grids, power systems face issues, such as stability and harmonic resonance; broadband harmonic impedance is a key piece of information that helps analyze these issues. This study proposes a non-injected broadband impedance estimation method based on injected method impedance measurement. First, a two-stage operational states classification method was conceived based on multi-domain features. Second, an operational states matching method was proposed to associate the concerned-time power quality monitoring data with the pre-classified states, based on Pearson correlation. Third, a regularized optimization model was developed to estimate the broadband impedance curve. Finally, a grid-connected inverter system under different control strategies was constructed as a case study. The simulations demonstrated that the accuracy of the proposed methodology was more than 90% for all the operational states defined in the case study, thus it obviates the need for perturbation injection as in traditional methods to enable real-time broadband impedance measurement.

International Journal of Electrical Power & Energy SystemsVol. 172
State Grid Corporation of China (China) (CN), Sichuan University (CN), Shanghai Electric (China) (CN)
Openalex Percentile: Top 64%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.