IlluC-Net: An attention-guided U-Net for illumination correction in dermatological macro-photographs
Uneven illumination in dermatological macro-photographs presents a significant challenge for accurate analysis of skin lesions, affecting both clinical diagnosis and the performance of automated tools used to diagnose skin cancer. To address this issue, we propose IlluC-Net, a novel deep learning framework designed for illumination correction in dermatological macro-photographs. IlluC-Net is designed on a U-Net architecture integrated with attention mechanisms to effectively capture both local and global features from the macro-photographs. This approach equalizes the background illumination while preserving the structure of the lesion. The IlluC-Net model is trained using the mean squared error (MSE) loss function, with dynamic learning rate scheduling and early stopping strategies are employed to prevent overfitting. The performance of IlluC-Net is evaluated using a curated set of dermatological macro-photographs from the University of Waterloo skin cancer dataset and MED-NODE dataset under five-fold cross-validation. Quantitative results show that IlluC-Net outperforms existing state-of-the-art (SOTA) illumination correction methods, including U-Net, TransUNet, GAN, EnlightenGAN, CSWin-P, and IECET, achieving the highest PSNR of 35.99 ± 3.15 dB and SSIM of 0.98 ± 0.01, while obtaining the lowest BRISQUE, PIQE, and NIQE scores of 27.09 ± 10.43, 44.39 ± 9.77, and 0.27 ± 0.02, respectively, across all test images. Visual evaluations further confirm that the illumination-corrected images produced by IlluC-Net closely resemble the ground-truth images, exhibiting minimal visual artifacts and enhanced contrast. Owing to its superior performance and computational efficiency, IlluC-Net is well-suited for integration into computer-aided diagnosis (CAD) systems and can be effectively deployed on edge devices for real-time diagnosis. • A U-Net-based deep learning model with attention for correcting uneven illumination in dermatological macro-images. • Preserves lesion structure while equalizing background lighting, enhancing diagnostic accuracy. • Outperforms SOTA methods, achieving the highest PSNR of 35.99 dB and SSIM of 0.98, while obtaining the lowest BRISQUE, PIQE, and NIQE scores of 27.09, 44.39, and 0.27, respectively. • Efficient and lightweight, suitable for integration into CAD systems and mobile health applications.
Authors
- Vipin Venugopal (ORCID: https://orcid.org/0000-0002-7943-8923)
- Sai Harshavardhan (ORCID: https://orcid.org/0009-0007-6328-6690)
- Ruthvik Guptha
- Likith Adithya (ORCID: https://orcid.org/0009-0000-0261-0425)
- Anoop B.N. (ORCID: https://orcid.org/0000-0002-6082-391X)
- Gowtham Sai Chandra (ORCID: https://orcid.org/0009-0002-3535-8902)
Institutions
- Manipal Academy of Higher Education (IN)
- Amrita Vishwa Vidyapeetham (IN)
Publication Details
- Journal
- Franklin Open
- Published
- 2025-11-21
- DOI
- https://doi.org/10.1016/j.fraope.2025.100439
- Primary Topic
- Cutaneous Melanoma Detection and Management
- Type
- article
- Field-Weighted Citation Impact
- 0.00