Influence of medical metal implants in the craniofacial area on the accuracy of quantitative magnetic resonance relaxometry within brain-related ranges at 3 T

<i>Objective.</i>To evaluate how medical metal implants influence<i>T</i><sub>1</sub>and<i>T</i><sub>2</sub>mapping in magnetic resonance imaging (MRI), focusing on relaxation quantification accuracy and repeatability.<i>Approach.</i>The National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine phantom was scanned on three 3 T MRI systems at different sites using variable flip angle (VFA), multi-echo fast spin echo (ME-FSE), and MR fingerprinting (MRF). Repeatability and accuracy were assessed, followed by analysis of the effects of aneurysm clips, cranial plates, and orthodontic materials.<i>Main results.</i>Coefficient of variation of 2.44%-10.81% for VFA/ME-FSE and 1.67%-16.31% for MRF. Deviations from reference values ranged from 5.96%-132.26% for VFA/ME-FSE and -36.87%-17.17% for MRF. When metal implants were introduced, VFA remained more robust for<i>T</i><sub>1</sub>mapping while MRF and ME-FSE only quantified spheres distal to the metal reliably.<i>B</i><sub>0</sub>/<i>B</i><sub>1</sub><sup>+</sup>mapping sequence effectively delineated artifact boundaries and guide reliable regions for relaxometry imaging.<i>Significance.</i>Medical metal implants can substantially affect relaxation quantification in MRI, with distortion severity depending on implant type and distance. These findings highlight the importance of accounting for these effects when interpreting quantitative MRI results in both clinical and research settings.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-11-21
DOI
https://doi.org/10.1088/1361-6560/ae22b9
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of medical metal implants in the craniofacial area on the accuracy of quantitative magnetic resonance relaxometry within brain-related ranges at 3 T

Yanglei Wu, Wenzheng Luo, Gaoyang Zhao, Shanshan Zhao et al.
Physics in Medicine and Biology
Advanced MRI Techniques and Applications
article

Influence of medical metal implants in the craniofacial area on the accuracy of quantitative magnetic resonance relaxometry within brain-related ranges at 3 T

Yanglei Wu, Wenzheng Luo, Gaoyang Zhao, Shanshan Zhao, Jingliang Cheng, Yong Zhang, Xiaoyue Ma, Mengzhu Wang, Changhe Pang
article en

Abstract

<i>Objective.</i>To evaluate how medical metal implants influence<i>T</i><sub>1</sub>and<i>T</i><sub>2</sub>mapping in magnetic resonance imaging (MRI), focusing on relaxation quantification accuracy and repeatability.<i>Approach.</i>The National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine phantom was scanned on three 3 T MRI systems at different sites using variable flip angle (VFA), multi-echo fast spin echo (ME-FSE), and MR fingerprinting (MRF). Repeatability and accuracy were assessed, followed by analysis of the effects of aneurysm clips, cranial plates, and orthodontic materials.<i>Main results.</i>Coefficient of variation of 2.44%-10.81% for VFA/ME-FSE and 1.67%-16.31% for MRF. Deviations from reference values ranged from 5.96%-132.26% for VFA/ME-FSE and -36.87%-17.17% for MRF. When metal implants were introduced, VFA remained more robust for<i>T</i><sub>1</sub>mapping while MRF and ME-FSE only quantified spheres distal to the metal reliably.<i>B</i><sub>0</sub>/<i>B</i><sub>1</sub><sup>+</sup>mapping sequence effectively delineated artifact boundaries and guide reliable regions for relaxometry imaging.<i>Significance.</i>Medical metal implants can substantially affect relaxation quantification in MRI, with distortion severity depending on implant type and distance. These findings highlight the importance of accounting for these effects when interpreting quantitative MRI results in both clinical and research settings.

Physics in Medicine and BiologyVol. 70(23)
Henan Tianguan Group (China) (CN), Imaging, Brain, and Neuropsychiatry (FR), Henan University of Engineering (CN), Berlin Institute of Health at Charité - Universitätsmedizin Berlin (DE), Siemens Healthcare (United States) (US), First Affiliated Hospital of Zhengzhou University (CN), Charité - Universitätsmedizin Berlin (DE)
Openalex Percentile: Top 49%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.