Enhanced Visualization of Intracranial Cortical Arteries Using Deep Learning Reconstruction in Vessel Wall MR Imaging

This study evaluated the utility of deep learning reconstruction (DLR) in vessel wall imaging (VWI) for visualizing the entire cerebral arterial system, including cortical arteries. Seventeen patients underwent post-contrast 3D T1WI-CUBE VWI with 0.5 mm isotropic resolution. Images with and without DLR were compared using qualitative and quantitative assessments. Qualitative image quality was rated on a 4-point scale across 29 arterial segments, including the internal carotid, vertebral, basilar, and the 1st to 4th segments of the major cerebral arteries. Quantitative evaluation of the vertebral artery wall assessed SNR and contrast-to-noise ratio (CNR). DLR significantly improved overall image quality compared to the without-DLR group, with cortical arteries rated as optimal in all cases with DLR (all P < 0.001). SNR and CNR were also significantly higher with DLR (P = 0.004). These results suggest that DLR enables high-resolution VWI of intracranial cortical arteries within a clinically acceptable scan time.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medical Sciences
Published
2025-11-21
DOI
https://doi.org/10.2463/mrms.tn.2025-0091
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Visualization of Intracranial Cortical Arteries Using Deep Learning Reconstruction in Vessel Wall MR Imaging

Satoru Ide, Yu Murakami, Yuta Yoshimatsu, Koichiro Futatsuya et al.
Magnetic Resonance in Medical Sciences
Cerebrovascular and Carotid Artery Diseases
article

Enhanced Visualization of Intracranial Cortical Arteries Using Deep Learning Reconstruction in Vessel Wall MR Imaging

Satoru Ide, Yu Murakami, Yuta Yoshimatsu, Koichiro Futatsuya, Keiko Kajio, N Ogawa, Hirotaka Inoue, Toshihiro Sakamoto, Takatoshi Aoki
article en

Abstract

This study evaluated the utility of deep learning reconstruction (DLR) in vessel wall imaging (VWI) for visualizing the entire cerebral arterial system, including cortical arteries. Seventeen patients underwent post-contrast 3D T1WI-CUBE VWI with 0.5 mm isotropic resolution. Images with and without DLR were compared using qualitative and quantitative assessments. Qualitative image quality was rated on a 4-point scale across 29 arterial segments, including the internal carotid, vertebral, basilar, and the 1st to 4th segments of the major cerebral arteries. Quantitative evaluation of the vertebral artery wall assessed SNR and contrast-to-noise ratio (CNR). DLR significantly improved overall image quality compared to the without-DLR group, with cortical arteries rated as optimal in all cases with DLR (all P < 0.001). SNR and CNR were also significantly higher with DLR (P = 0.004). These results suggest that DLR enables high-resolution VWI of intracranial cortical arteries within a clinically acceptable scan time.

Magnetic Resonance in Medical SciencesVol. 25(1)
University of Occupational and Environmental Health Japan (JP)
Hirosaki University
Openalex Percentile: Top 49%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.