A standardized robot-assisted technique for giant paraesophageal hernia repair: the relationship between surgical details and low recurrence rate in long-term follow-up

Giant Hiatal Hernia (GHH) is defined as a hiatal hernia that includes at least 30–50% of stomach in the chest. Laparoscopic approach may be challenging with high recurrence rates. Robotic surgery may overcome some laparoscopic limits, but its role is still debated. We analysed a multicentric prospective database from 2011 to 2023 at General and Robotic Surgery Unit of San Giovanni Battista Hospital (Foligno-Spoleto, Italy) and General Surgery Unit of San Donato Hospital (Arezzo, Italy). A Robotic-Assisted Repair (RAR) was performed in all cases following a standardized surgical technique consisting of 6 steps. A literature review was carried out to identify surgical details linked to better outcomes. 47 consecutive patients underwent RAR. Four procedures were performed in emergency setting and 2 were redo-surgery. 1 (2%) conversion to open was required. Mean operative time was 158 min (range 90–235), and mean length of stay was 2.9 days (range 2–7). Fundoplication was performed in 97% of cases, while cruroplasty using pladgets in the 100%. Bioabsorbable mesh was used in 95% of patients. Anterior gastropexy or gastrostomy was made in the 85%. No patients were readmitted within 30 days, while 3 (6%) showed radiologic recurrences without clinical symptoms at long-term follow-up. A standardized surgical technique in GHH repair achieves lower postoperative complications and recurrence rates even in a long-term follow-up. Robotic platforms allow for safer and technically easier procedures, also in emergency scenarios. Higher costs may be balanced by better postoperative outcomes when compared to conventional literature laparoscopic outcomes.

Authors

Institutions

Publication Details

Journal
Langenbeck s Archives of Surgery
Published
2025-11-21
DOI
https://doi.org/10.1007/s00423-025-03925-z
Primary Topic
Gastroesophageal reflux and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A standardized robot-assisted technique for giant paraesophageal hernia repair: the relationship between surgical details and low recurrence rate in long-term follow-up

Germano Guerra, Pasquale Avella, Gaetano Poillucci, Fabio Rondelli et al.
Langenbeck s Archives of Surgery
Gastroesophageal reflux and treatments
article

A standardized robot-assisted technique for giant paraesophageal hernia repair: the relationship between surgical details and low recurrence rate in long-term follow-up

Germano Guerra, Pasquale Avella, Gaetano Poillucci, Fabio Rondelli, Michele De Rosa, Aldo Rocca, Brian WCA Tian, Andrea Scacchi, Graziano Ceccarelli, Pajtim Emini, Alessandro Spaziani, Fausto Catena
article en

Abstract

Giant Hiatal Hernia (GHH) is defined as a hiatal hernia that includes at least 30–50% of stomach in the chest. Laparoscopic approach may be challenging with high recurrence rates. Robotic surgery may overcome some laparoscopic limits, but its role is still debated. We analysed a multicentric prospective database from 2011 to 2023 at General and Robotic Surgery Unit of San Giovanni Battista Hospital (Foligno-Spoleto, Italy) and General Surgery Unit of San Donato Hospital (Arezzo, Italy). A Robotic-Assisted Repair (RAR) was performed in all cases following a standardized surgical technique consisting of 6 steps. A literature review was carried out to identify surgical details linked to better outcomes. 47 consecutive patients underwent RAR. Four procedures were performed in emergency setting and 2 were redo-surgery. 1 (2%) conversion to open was required. Mean operative time was 158 min (range 90–235), and mean length of stay was 2.9 days (range 2–7). Fundoplication was performed in 97% of cases, while cruroplasty using pladgets in the 100%. Bioabsorbable mesh was used in 95% of patients. Anterior gastropexy or gastrostomy was made in the 85%. No patients were readmitted within 30 days, while 3 (6%) showed radiologic recurrences without clinical symptoms at long-term follow-up. A standardized surgical technique in GHH repair achieves lower postoperative complications and recurrence rates even in a long-term follow-up. Robotic platforms allow for safer and technically easier procedures, also in emergency scenarios. Higher costs may be balanced by better postoperative outcomes when compared to conventional literature laparoscopic outcomes.

Langenbeck s Archives of SurgeryVol. 411(1)
University of Molise (IT), Singapore General Hospital (SG), Azienda Ospedaliero Universitaria San Giovanni Battista (IT), Ospedale di Spoleto (IT), Ospedale “M. Bufalini” di Cesena (IT), Villa Pineta Hospital (IT), Center for Special Minimally Invasive and Robotic Surgery (US), University of Milano-Bicocca (IT), University of Naples Federico II (IT)
Openalex Percentile: Top 49%
Gastroesophageal reflux and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.