Azure Kinect for joint range of motion analysis: A validity and reliability evaluation in elite female weightlifters

Kinect is a markerless, portable, and affordable motion analysis tool used in clinical, rehabilitation, and sports settings. This study aimed to assess upper limb (shoulder and elbow) and cervical joint angles in elite female weightlifters using Azure Kinect and a digital goniometer, and to evaluate the Kinect's validity and reliability. Joint angles were measured in elite female weightlifters (n = 21) using both a digital goniometer and Azure Kinect, with three repetitions per movement under standardized conditions (within a stabilization cage). Mean values were used for analysis. Statistical analysis included descriptive metrics and non-parametric tests. Tool comparisons were conducted using the Wilcoxon signed-rank test, Spearman's correlation coefficient, and Bland-Altman plots. Reliability was evaluated through the Intraclass Correlation Coefficient (ICC), Coefficient of Variation (CV), and Coefficient of Repeatability (CR), with statistical significance set at p < 0.05. Most joint angle measurements showed no statistically significant differences between the digital goniometer and Azure Kinect (p > 0.05), although small discrepancies appeared in some movements. High correlation coefficients (r = 0.82-0.99) and strong agreement based on Intraclass Correlation Coefficient (ICC = 0.97-0.99) were observed. Bland-Altman analysis revealed minimal systematic bias and narrow confidence intervals. Comparable values in Coefficient of Variation (CV) and Coefficient of Repeatability (CR) indicated high stability and repeatability for both tools. Overall, results support Azure Kinect as a valid and reliable alternative to traditional digital goniometry for assessing cervical and upper extremity joint range of motion.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-11-21
DOI
https://doi.org/10.1371/journal.pone.0334890
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Azure Kinect for joint range of motion analysis: A validity and reliability evaluation in elite female weightlifters

Serkan Örücü, Erkan Özbay, Kenan Erdağı, Usame Ömer Osmanoğlu et al.
PLoS ONE
Shoulder Injury and Treatment
article

Azure Kinect for joint range of motion analysis: A validity and reliability evaluation in elite female weightlifters

Serkan Örücü, Erkan Özbay, Kenan Erdağı, Usame Ömer Osmanoğlu, Bülent Işık
article en

Abstract

Kinect is a markerless, portable, and affordable motion analysis tool used in clinical, rehabilitation, and sports settings. This study aimed to assess upper limb (shoulder and elbow) and cervical joint angles in elite female weightlifters using Azure Kinect and a digital goniometer, and to evaluate the Kinect's validity and reliability. Joint angles were measured in elite female weightlifters (n = 21) using both a digital goniometer and Azure Kinect, with three repetitions per movement under standardized conditions (within a stabilization cage). Mean values were used for analysis. Statistical analysis included descriptive metrics and non-parametric tests. Tool comparisons were conducted using the Wilcoxon signed-rank test, Spearman's correlation coefficient, and Bland-Altman plots. Reliability was evaluated through the Intraclass Correlation Coefficient (ICC), Coefficient of Variation (CV), and Coefficient of Repeatability (CR), with statistical significance set at p < 0.05. Most joint angle measurements showed no statistically significant differences between the digital goniometer and Azure Kinect (p > 0.05), although small discrepancies appeared in some movements. High correlation coefficients (r = 0.82-0.99) and strong agreement based on Intraclass Correlation Coefficient (ICC = 0.97-0.99) were observed. Bland-Altman analysis revealed minimal systematic bias and narrow confidence intervals. Comparable values in Coefficient of Variation (CV) and Coefficient of Repeatability (CR) indicated high stability and repeatability for both tools. Overall, results support Azure Kinect as a valid and reliable alternative to traditional digital goniometry for assessing cervical and upper extremity joint range of motion.

PLoS ONEVol. 20(11)
Necmettin Erbakan University (TR), Karamanoğlu Mehmetbey University (TR)
Openalex Percentile: Top 45%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.