Long-Term Performance Evaluation of an FRP Composite Road Bridge Using DFOS Monitoring System

FRP composite bridges have been in operation since the mid-1990s, allowing for the evaluation of their long-term behaviour. Many of the early FRP bridges in the USA and Western Europe were equipped with monitoring systems to assess their structural integrity after years of use. In Poland, the first all-FRP composite bridge was also equipped with a modern structural health monitoring (SHM) system based on distributed fibre optic sensing (DFOS) to enable long-term performance monitoring. Over nearly a decade of use, the bridge's strain, stiffness, and dynamic properties have been evaluated three times through static and dynamic load tests. Research findings indicate that the bridge has maintained satisfactory structural integrity and durability over an eight-year operational period. However, the quality of the adhesive joints between the girders and the deck panels was found to be inadequate, resulting in a slight decrease in the bridge's performance, specifically in stiffness and dynamic characteristics. Fortunately, these negative changes did not compromise the bridge's safety or serviceability, as stipulated by the design requirements. An effective repair was completed, restoring the bridge to its full operational efficiency.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-11-21
DOI
https://doi.org/10.3390/s25237131
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Term Performance Evaluation of an FRP Composite Road Bridge Using DFOS Monitoring System

Maciej Kulpa, Tomasz Siwowski, Ewa Błazik‐Borowa, Mateusz Rajchel et al.
Sensors
Structural Health Monitoring Techniques
article

Long-Term Performance Evaluation of an FRP Composite Road Bridge Using DFOS Monitoring System

Maciej Kulpa, Tomasz Siwowski, Ewa Błazik‐Borowa, Mateusz Rajchel, Michał Jukowski
article en

Abstract

FRP composite bridges have been in operation since the mid-1990s, allowing for the evaluation of their long-term behaviour. Many of the early FRP bridges in the USA and Western Europe were equipped with monitoring systems to assess their structural integrity after years of use. In Poland, the first all-FRP composite bridge was also equipped with a modern structural health monitoring (SHM) system based on distributed fibre optic sensing (DFOS) to enable long-term performance monitoring. Over nearly a decade of use, the bridge's strain, stiffness, and dynamic properties have been evaluated three times through static and dynamic load tests. Research findings indicate that the bridge has maintained satisfactory structural integrity and durability over an eight-year operational period. However, the quality of the adhesive joints between the girders and the deck panels was found to be inadequate, resulting in a slight decrease in the bridge's performance, specifically in stiffness and dynamic characteristics. Fortunately, these negative changes did not compromise the bridge's safety or serviceability, as stipulated by the design requirements. An effective repair was completed, restoring the bridge to its full operational efficiency.

SensorsVol. 25(23)
Rzeszów University of Technology (PL), Medical University of Lublin (PL), Lublin University of Technology (PL), University of Rzeszów (PL)
Openalex Percentile: Top 63%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Long-Term Performance Evaluation of an FRP Composite Road Bridge Using DFOS Monitoring System — Maciej Kulpa, Tomasz Siwowski, et al. · Sensors (2025) | TGRS Research Map | TGRS