Gaseous detector calibration and efficiency filter evaluation for radiochemistry facility

ICRP 103 guidelines and EURATOM Directive 2013/59 require close monitoring of radioactive emissions, ensuring that public exposure remains below 10 $\mu $Sv/year. To meet these limits, reliable and accurate monitoring systems are essential. This study presents a method for calibrating large-area proportional counters used for monitoring the emissions of $^{18}F$ and $^{11}C$ gases during the production of PET radiopharmaceuticals. The proposed method makes it possible to accurately determine the calibration factor for measuring the air activity concentration. In addition, the efficiency of absolute and activated carbon filters in reducing radioactive emissions was evaluated. The results showed a filtration efficiency of 98$\%$. This underscores the importance of combining detection system with efficient air filtration to ensure that radionuclide production facilities remain within regulatory limits, protecting both public health and the environment.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-11-21
DOI
https://doi.org/10.1093/rpd/ncaf136
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gaseous detector calibration and efficiency filter evaluation for radiochemistry facility

Juan Alberto Berrios-Mejía, Roberto Di Giorgio, Pedro Antonio, Rapisarda Giuseppe Gabriele et al.
Radiation Protection Dosimetry
Radioactive Decay and Measurement Techniques
article

Gaseous detector calibration and efficiency filter evaluation for radiochemistry facility

Juan Alberto Berrios-Mejía, Roberto Di Giorgio, Pedro Antonio, Rapisarda Giuseppe Gabriele, Sciortino Marcella, Ippolito Massimo, Scopelliti Fabrizio, Sabini Maria Gabriella, Gallitto Giulia
article en

Abstract

ICRP 103 guidelines and EURATOM Directive 2013/59 require close monitoring of radioactive emissions, ensuring that public exposure remains below 10 $\mu $Sv/year. To meet these limits, reliable and accurate monitoring systems are essential. This study presents a method for calibrating large-area proportional counters used for monitoring the emissions of $^{18}F$ and $^{11}C$ gases during the production of PET radiopharmaceuticals. The proposed method makes it possible to accurately determine the calibration factor for measuring the air activity concentration. In addition, the efficiency of absolute and activated carbon filters in reducing radioactive emissions was evaluated. The results showed a filtration efficiency of 98$\%$. This underscores the importance of combining detection system with efficient air filtration to ensure that radionuclide production facilities remain within regulatory limits, protecting both public health and the environment.

Radiation Protection DosimetryVol. 201(20)
University of Catania (IT), Institute of Molecular Bioimaging and Physiology (IT), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (IT), Ospedale Cannizzaro (IT), University of Palermo (AR), University of Palermo (IT)
Openalex Percentile: Top 55%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.