Self-Powered PEC Cathodic Immunosensor for CA125 Detection Based on the Cu <sub>2</sub> O Photocathode and the CdS/PANI Photoanode

The photoelectrochemical (PEC) biosensors relying on anodic photocurrent modulation are prone to producing false-positive results due to the interference from reductive species in samples, while the PEC sensors based on cathodic response often exhibit insufficient sensitivity in practical applications. To address this issue, herein we synthesized CdS via a hydrothermal method and encapsulated it with polyaniline (PANI) to create a high-performance CdS/PANI heterojunction photosensitive material. Then, the composite was used as a photoanode, paired with the Cu<sub>2</sub>O photocathode, establishing a self-powered system, wherein the CdS/PANI photoanode supplied photogenerated electrons to the Cu<sub>2</sub>O photocathode. Owing to the strong driving force provided by the Fermi-level difference between CdS/PANI and Cu<sub>2</sub>O for electron migration, the dual-photoelectrode system produced a strong and stable cathodic response signal, which was up to 23 times that of a three-electrode system, laying the foundation for constructing a highly sensitive sensor. On this basis, the Cu<sub>2</sub>O electrode functioning as a working electrode was modified by electrodeposited gold nanoparticles (Au NPs), followed by the immobilization of recognition element CA125 antibody through Au-N bonds, targeting the model molecule carbohydrate antigen CA125. Consequently, the obtained self-powered dual-photoelectrode immunosensor demonstrated exceptional analytical performance, including a wide quantitative detection range of 0.001-100 ng mL<sup>-1</sup>, a low detection limit of 0.26 pg mL<sup>-1</sup>, high stability, reproducibility, anti-interference capability, and practicability. Furthermore, this sensing platform is readily adaptable to monitoring other disease biomarkers.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-11-21
DOI
https://doi.org/10.1021/acssensors.5c03044
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Powered PEC Cathodic Immunosensor for CA125 Detection Based on the Cu 2 O Photocathode and the CdS/PANI Photoanode

Faqiong Zhao, Baizhao Zeng, Xuyong Wang, Shulei Wang
ACS Sensors
Advanced biosensing and bioanalysis techniques
article

Self-Powered PEC Cathodic Immunosensor for CA125 Detection Based on the Cu 2 O Photocathode and the CdS/PANI Photoanode

Faqiong Zhao, Baizhao Zeng, Xuyong Wang, Shulei Wang
article en

Abstract

The photoelectrochemical (PEC) biosensors relying on anodic photocurrent modulation are prone to producing false-positive results due to the interference from reductive species in samples, while the PEC sensors based on cathodic response often exhibit insufficient sensitivity in practical applications. To address this issue, herein we synthesized CdS via a hydrothermal method and encapsulated it with polyaniline (PANI) to create a high-performance CdS/PANI heterojunction photosensitive material. Then, the composite was used as a photoanode, paired with the Cu<sub>2</sub>O photocathode, establishing a self-powered system, wherein the CdS/PANI photoanode supplied photogenerated electrons to the Cu<sub>2</sub>O photocathode. Owing to the strong driving force provided by the Fermi-level difference between CdS/PANI and Cu<sub>2</sub>O for electron migration, the dual-photoelectrode system produced a strong and stable cathodic response signal, which was up to 23 times that of a three-electrode system, laying the foundation for constructing a highly sensitive sensor. On this basis, the Cu<sub>2</sub>O electrode functioning as a working electrode was modified by electrodeposited gold nanoparticles (Au NPs), followed by the immobilization of recognition element CA125 antibody through Au-N bonds, targeting the model molecule carbohydrate antigen CA125. Consequently, the obtained self-powered dual-photoelectrode immunosensor demonstrated exceptional analytical performance, including a wide quantitative detection range of 0.001-100 ng mL<sup>-1</sup>, a low detection limit of 0.26 pg mL<sup>-1</sup>, high stability, reproducibility, anti-interference capability, and practicability. Furthermore, this sensing platform is readily adaptable to monitoring other disease biomarkers.

ACS SensorsVol. 11(1)
Hunan University (CN), Wuhan University (CN)
Openalex Percentile: Top 68%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.